replacing the Filters
Pump Filter
1. Loosen and remove the filter
body by hand.
2. Slip the filter off of the core
spring.
3. Inspect the filter. Based on
inspection, clean or replace the
filter.
4. Inspect the o-ring. Based on
inspection, clean or replace the
o-ring.
5. Slide the new or cleaned filter
over the core spring with the
filter spring adapter in place.
Push the filter into the center of
the filter housing.
6. Slide the filter body over the
filter and thread it into the filter
housing until secure.
NOTE: The filter housing
should be hand-
tightened, but make
sure the filter housing
is seated fully into the
pump block.
Gun Filter
1. Move the gun trigger lock to the unlocked position.
2. Loosen and remove the handle from the gun body.
3. Turning clockwise, unscrew the filter from the gun body.
NOTE: Left-handed threads require turning the filter
clockwise to remove.
4. Turning counterclockwise, screw the new or cleaned filter into
the gun body.
5. Make sure the handle seal is in position and thread the handle
into the gun body until secure.
6. Move the gun trigger lock to the locked position.
English
Filter Body
Filter Spring
Filter
Filter Spring
Adapter
Core Spring
O-ring
Filter Housing
Gun
Body
Filter
Handle
Seal
Handle
replacing the motor assembly
1. Unplug the unit.
2. Loosen and remove the two (2) motor shroud screws. Remove
the motor shroud.
3. Loosen and remove the three (3) belly pan screws. Remove
the belly pan.
4. Loosen and remove the two (2) motor cover screws. Remove
the motor cover.
5. Disconnect all wires between the motor and the sprayer.
6. Loosen and remove the four (4) control panel screws. Remove
the control panel.
7. Disconnect the wires between the motor and the control
panel.
8. Loosen and remove the two (2) motor controller screws.
Remove the motor controller.
9. Loosen and remove the four (4) motor baffle screws. Remove
the motor baffle.
10. Loosen and remove the six (6) motor mounting screws.
11. Pull the motor out of the gearbox housing.
12. With the motor removed, inspect the gears in the gearbox
housing for damage or excessive wear. Replace the gears, if
necessary.
13. Install the new motor into the gearbox housing.
14. Secure the motor with the six (6) motor mounting screws.
15. Reconnect the wires between the sprayer and the new motor.
(refer to the electrical schematic in the Parts List section of this
manual).
16. Place the baffle over the end of the motor assembly. Secure
with the four (4) motor baffle screws.
17. Place motor controller back into place behind the motor
baffle. Secure with the two (2) motor controller screws.
18. Reconnect all wires between the motor and sprayer.
19. Reconnect the wires between the motor and the control
panel.
20. Replace control panel and secure with four (4) control panel
screws.
21. Place the motor cover back over the motor controller. Secure
with the two (2) motor cover screws.
22. Put the belly pan back in place and secure with the three (3)
belly pan screws.
23. Slide the motor shroud over the motor assembly.
24. Secure the motor shroud with the two (2) motor shroud
screws.
Control
Gearbox
Panel
housing
Screw
Control
Panel
Belly Pan
Screw
Motor
Belly Pan
Shroud
Screw
Motor Controller Screw
10
Motor Shroud
Motor Mounting
Screw
Motor
Motor
Ba e
Motor Ba e
Screw
Motor Controller
Motor Cover
Motor Cover Screw