Télécharger Imprimer la page

Raypak Crosswind V TWPH 4550 Manuel D'installation Et D'utilisation page 83

Publicité

Les langues disponibles

Les langues disponibles

SOLAR
WATER IN
SENSOR
(TO POOL
OR SPA)
PUMP
4. Follow the general instructions for wiring external
devices and route the wires for the "Solar sensor" and
"Solar 3-way valve" to the control box of the heater.
5. Inside the control box of the heater, connect the
wires for the "Solar sensor" to the control board
terminal labeled as "SOLAR" [P11] using the harness
adapter labeled as "Solar Temperature Sensor /
Auxiliary Safety Input" provided in the accessories
bag. Connect the Red with White wires for a 10K
temperature sensor and use the terminal [P9] to
connect a standard 3-way valve actuator for the
"Solar 3-way valve". Refer to Figure 155 for details.
6. Enable the "Solar Heating" option and configure
the necessary parameters based on your system
requirements and operation preferences from the
Installer menu. Refer to section 13 in page 21 for
further details on configuring the Solar Heating
function.
APPROVED
SOLAR COLLECTOR
INLET OUTLET
FILTER
SOLAR 3-WAY
VALVE
Figure 154. Solar Heater Components in the Piping
UNCONTROLLED DOCUMENT IF PRINTED
CHECK
VALVE
Solar 3-way valve
actuator
Solar Sensor (10K)
Figure 155. Solar Heat & Auxiliary Input
SOLAR HEAT
& AUX INPUT
P11
P9
P2
WPS
LPS
HPS
P3
FAN
RVS
COMP
83