Télécharger Imprimer la page

cecotec CONGA ROCKSTAR 2500 X-TREME Manuel D'instructions page 27

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 29
ENGLISH
Filters and tank cleaning
-
To avoid the appliance from overheating and losing suction power, it is essential to clean
the filters regularly. To make the most of the suction power, it is suggested to clean the
filter after each use.
-
The service life of the filters will depend on the accumulated usage and the type of
particles that are regularly vacuumed. It is recommended that you replace the filters every
6 months.
-
To take the filters out (Fig.12):
1.
Press the dust tank opening button, marked with the word "CLEAN", and pull on the
metallic handle to remove the filtering system.
2.
Once the filtering system is out, turn the metallic handle anticlockwise and remove the
high-efficiency filter.
-
You can wash the high-efficiency filter with warm water (Fig. 13). However, it is
recommended to vacuum or shake it out, to prevent the filter from getting wet or damp
and affecting the performance of the vacuum cleaner.
-
If you decide to wash it, make sure it is completely dry before installing it again on the
device.
-
Filters cannot be washed inside a washing machine nor dried with a hair dryer.
-
Do not brush the filter.
-
To empty the dust tank, press the dust tank lower opening button, open it and empty it.
Fig. 14
Cleaning the Jaliscazo brush
Fig. 15
1.
Move the rotary brush release button with the finger toward the arrow and remove the
cover on the same side of the brush.
2.
Remove one end of the brush as shown on the image.
-
It is important to clear and clean all the residues left in the brush rotary axis.
-
If you decide to wash the brush you must let all parts dry. Assemble it back in order to use
the brush again.
How to remove the battery
Press the battery release button and remove the battery as shown on the image. Store the
battery in a plastic bag and leave it in a dry place. Fig. 16
Storing the device
-
If the vacuum cleaner is not going to be used for a long time, remove the battery from the
product and store it in a dry and safe place.
Maintenance indicator
-
The full tank icon or the clogged filter icon will be displayed if the device has not been
properly and frequently maintained. Fig. 17
52
6. TROUBLESHOOTING
Problem
Possible cause
The motor does not operate
The battery does not work
any longer.
The metallic tubes, floor
brushes, batteries or the
device itself are not properly
assembled.
The suction power has been
The dust tank is full.
reduced and the appliance
The filter has too much dust.
makes a lot of noise.
The electric rotary brush inlet
Fig. 17
is obstructed or the brush is
blocked.
Insufficient operating time
Insufficient charge time.
after charge.
The battery is old.
(The battery life may vary
according to the room
temperature).
7. ERROR CODES
Code
Problem
E1
The device turns off and does not
charge
E2
The device does not charge
E2
The device does not charge
The device turns off
E3
The device turns off and displays E3
E5
The device turns off and displays E5
E6
The device turns off and displays E6
ENGLISH
Solution
Charge the vacuum cleaner.
Make sure all parts of
the device are correctly
assembled.
Clean the dirt.
Clean or replace the filter.
Clean the dust inside the
electric rotary brush.
Fully charge the battery
following the instructions in
this manual.
Batteries are easily
recycled. Go to the closest
maintenance point and buy
new batteries.
Cause
Short circuit
The charger voltage is below 36.3 V
The charger voltage is below 32.1 V
Low battery
The motor short-circuits when the
battery is low
Main motor overload (second level)
Main motor overload