OR SHOWERS. This means that it cannot be installed in the are-
as marked as VOLUME 1 in picture 2.
During function, place the heater in a safe position:
-
at least 1m far from inflammable objects or furnitures;
-
leaving not less than 1m of free space in front of the heater;
-
not located immediately below a socket-outlet.
Do not leave animals or children touch or play with the appliance.
Pay attention! The air outlet grille gets hot during operation (more
than 90°C)
WARNING: In order to avoid overheating, do not cover the
heater. Do not hang anything on the heater and do not cover it
while it's working. This is clearly written on the cover of the pro-
duct or shown by the symbol
Do not use the heater in rooms with explosive gas or while using
inflammable solvents or varnish or glues.
If the cordset is damaged and you have to change it, do not do
the job yourselves! Take the product to an after sales authorised
repair centre or to a person with similar skill and knowledge, in
order to avoid any risk of danger.
The appliance must be positioned so that the plug is always ac-
cessible.
Do not mount the product on walls made of synthetic material.
2. W
all Mounting
Only fix the heater in vertical position with the air outlet grid downward;
This heater is fitted with a double electrical insulation circuit (class II) and therefore does not require an earth
connection.
This heater must be correctly installed in compliance with the regulations in force in the country of installation.
In wet spaces like bathrooms or kitchens, the connection terminal must be installed at least 25 cm above the
floor. The electrical connection to the power supply must also be fitted with a two-pole switch with a minimum
gap between the contacts that allows complete disconnection according to excess voltage III category conditions.
Always make observe the minimum distances from walls, furniture and/or objects, as indicated in picture 3. Never
install the product so that the distance between the floor and the lower side of the product is less than 600 mm:
-
Drill three 6 mm diameter holes in the wall, as shown in picture 4
-
Insert the three wall plugs supplied with the product
-
Insert the 2 upper screws, contained in the same bag, taking care to leave a distance of 8 mm between the
head of the screws and the wall;
-
Gripping the heater firmly, hook it onto the two screws; CAUTION! Before releasing the heater make sure
it is attached to the 2 screws.
-
Then secure the product with the lower screw.