Télécharger Imprimer la page

Koshin GEH-3100DX Instructions page 13

Publicité

Les langues disponibles

Les langues disponibles

EXTENSION CORDS
An extension cord should always be in good condition
with no damage to the wires or sheathing. Never run an
extension cord through water. The correct wire size for an
extension cord can be determined from the table that
follows.
Continuous
Minimum Cord Gauge (AWG)
Load
Amps
0-50 Feet
20
12
25
12
30
10
35
10
40
8
50
6
LOADING YOUR GENERATOR SET
With reference to the Receptacle details section, please
review the power receptacles fitted to your generator. The
circuit breaker rating and the generator rating drive the
actual load that may be pulled from each receptacle. The
ratings shown in the table are the maximum available from
each receptacle. DO NOT EXCEED THE INDIVIDUAL
RECEPTACLE RATINGS AS SHOWN IN THE TABLE
BELOW. DO NOT EXCEED THE TOTAL GENERATOR
RATING
SHOWN
IN
SPECIFICATIONS. All generator units are equipped with
a thermal-magnetic main circuit breaker as well as a
"PUSH TO RESET" breaker on branch circuits.
AMPERAGE RATE TABLE
Model
NEMA 5-20R
125V GFCI
GEH-3100DX
20Amps
ENGINE LIMITATIONS ON GENERATOR
PERFORMANCE
Generator ratings assume 60°F (20C) and Sea
Level. Operation of your generator at temperatures
above 60°F (20C) or above Sea Level will result in
lower electrical output. Electrical output must be
derated 1% for each 10°F above 60°F and 3 ½ %
for each 1000 feet above mean sea level.
0069297
50-100 Feet
100-150
Feet
10
8
10
6
8
6
8
4
6
2
4
2
TABLE
2
PERFORMANCE
NEMA L5-30R
125V
Twistlock
25Amps
GENERATOR CLEANING
CAUTION:
GENERATOR AND ALLOW IT TO COOL
COMPLETELY
CLEANING OPERATIONS.
WARNING: DO NOT USE HIGH PRESSURE
WATER OR A GARDEN HOSE TO CLEAN
YOUR GENERATOR. WATER INTRODUCED
INTO THE GENERATOR CAN CAUSE ELECTRICAL
SHORTS, GENERATOR DAMAGE OR PERSONAL
INJURY.
Compressed air (max. 25 psi) may be used to blow
loose dirt and dust from your generator. DO NOT
DIRECT COMPRESSED AIR DIRECTLY INTO ANY
OPENING IN THE GENERATOR OR ENGINE.
Use a dampened cloth to wipe clean exterior
surfaces.
Use a soft bristle brush to clean/ loosen heavy dirt, oil
or grease deposits.
NEVER insert rags, tools or any device into the
generator or engine openings.
GENERAL STORAGE GUIDELINES
WARNING: GASOLINE FUMES ARE FLAMMABLE. DO
NOT STORE YOUR GENSET IN ANY AREA THAT IS
INDOOR OR IN POORLY VENTILATED AREAS.
GASOLINE FUMES CAN IGNITE IN THE PRESENCE
OF ANY OPEN FLAME, PILOT LIGHT, CLOTHES
DRYER, WATER HEATER, ETC.
Your generator should be started and operated for
several minutes at least every 30 days.
If the generator cannot be operated every 30 days,
follow the storage recommendations within the engine
documentation.
NOTE: A fuel shut-off valve is positioned at the base
of the fuel tank. The valve should be closed during
storage periods.
13
ALWAYS
SHUT
DOWN
BEFORE
PERFORMING
English
THE

Publicité

loading