Télécharger Imprimer la page

Nok 820-0065G Manuel D'utilisation page 22

Publicité

Les langues disponibles

Les langues disponibles

LEAK TEST
WARNING:
CHECK ALL GAS SUPPLY FITTINGS FOR LEAKS BEFORE EACH USE. DO NOT USE THE GRILL UNTIL ALL
CONNECTIONS HAVE BEEN CHECKED AND DO NOT LEAK. DO NOT SMOKE WHILE LEAK-TESTING. NEVER
LEAK-TEST WITH AN OPEN FLAME.
GENERAL
Although gas connections on the grill are leak-tested prior to shipment, a complete leak test must be performed at the
installation site. Before each use, check all gas connections for leaks using the procedures listed below. If the smell of gas is
detected at any time, turn off gas supply and immediately check the entire system for leaks.
BEFORE TESTING
Make sure all packing materials have been removed from the grill, including the burner tie-down straps.
21
50 %
50 %
STEP 1
CREATE THE SOAPY WATER
Prepare a 50/50 solution of water and ammonia-free dish
detergent, to be applied using a spray bottle or brush.
STEP 2
CONNECTING THE REGULATOR TO THE LPG CYLINDER
1. Turn off the control valve at regulator to "OFF" by turning
clockwise until tight.
2. Install new LPG cylinder by pushing cylinder into regulator
and turn clockwise until tight. Place cylinder into cylinder
support bracket. Only disposable gas cylinder that can fit
within the support bracket shall be used.

Publicité

loading