Installation Requirements
Range Model
DOP48C96D**
13" (33.0 cm) max.
5
18" (45.7 cm)
4.5
Note 2
37 1/2"
(95.3 cm)
max.
1.
Vertical from range grate level to combustible overhead surface; if installing an overhead hood, see hood
specifications for minimum required clearances.
2.
Cabinet/countertop depth is at the customer's discretion, but cabinet face must not protrude beyond the rear
of the front panel. (See Product Dimensions, Pg. 13)
3.
Consult local codes for exact location requirements.
4.
Vertical from grate level to combustible surface.
5.
Does not apply to cabinets more than a horizontal distance of 10" (25.4 cm) from the range edge.
14
English
INSTALL_DOP48C96DLS_DA_DG68-01511A-00_EN+MES+CFR.indb 14
INSTALL_DOP48C96DLS_DA_DG68-01511A-00_EN+MES+CFR.indb 14
CUTOUT DIMENSIONS
A
54" (137.2 cm)*;
48" (121.9 cm)**
A
Non-combustible
Surface along back wall
recommended
Top of
finished
counter
30" (76.2 cm)
max.
1
B
Grate
level
Suggested
location of
utilities
3
Standard Cutout
with Range Hoof
B
48" (121.9 cm)**;
48 1/8" (122.2 cm)***
* Recommended, ** Minimum, *** Maximum
3/8" (1.0 cm) min.
flat countertop
overhang
Non-combustible rear
wall (recommended)
10" (25.4 cm) mín.
side walls above
10" (25.4 cm)
range (both sides)
min. to
combustible
Note 2
side walls
above range
(both sides)
Cutout with Optional Downdraft Vent
C
43 1/2" (110.5 cm)
Backsplash
3" (7.6 cm)
C
to combustible
B
(Top View)
2023-02-23 오전 9:45:25
2023-02-23 오전 9:45:25