Télécharger Imprimer la page

EGAmaster EGATRONIK Manuel D'instructions page 33

Publicité

Les langues disponibles

Les langues disponibles

Remark:
• Input impedance: 2MΩ.
• Frequency response: 40Hz~400Hz.
• Display effective value of sine wave (mean value response).
C.
DC Current
Range
2mA
20mA
200mA
20A
Remark:
• At 20A range: For continuous measurement ≤10 seconds and interval not less than 15
minutes.
• Measurement voltage drop: Full range at 200mV.
D.
AC Current
Range
20mA
200mA
20A
Remark:
• At 20 A range: For continuous measurement ≤10 seconds and interval not less than 15
minutes.
• Measurement voltage drop: Full range at 200mV.
• Frequency response: 40Hz~400Hz.
• Display effective value of sine wave (mean value response).
E.
Resistance Test
Range
200Ω
2kΩ
20kΩ
200kΩ
2MΩ
20MΩ
200MΩ
Remark:
• At 200MΩ range , test lead is in short circuit, and it is normal to display 1000 digits. During
measurement, subtract the 1000 digits from the reading.
All manuals and user guides at all-guides.com
Resolution
0.0001mA
0.001mA
0.01mA
0.001A
Resolution
0.001mA
0.01mA
0.001A
Resolution
0.1Ω
0.0001kΩ
0.001kΩ
0.01Ω
0.0001MΩ
0.001MΩ
0.01MΩ
±[5%(reading-1000)+10]
Accuracy
±(0.5%+5)
0.5A. 250V fast type fuse,
±(0.8%+5)
±(2%+10)
Accuracy
±(0.8%+10)
0.5A 250V fast type fuse,
±(1.2%+10)
±(2.5%+10)
Accuracy
±(0.5%+10)
±(0.3%+1)
±(0.5%+12)
Overload Protection
Ø5x20mm
Un-fused
Overload Protection
Ø5x20mm
Un-fused
Overload Protection
250V DC
or AC ms