Télécharger Imprimer la page

EGAmaster EGATRONIK Manuel D'instructions page 32

Publicité

Les langues disponibles

Les langues disponibles

Mesaurement Speed
Relative Humidity
Altitude: Operating
Battery Deficiency
Negative reading
Dimensions (HxWxL)
Safety/Compliances
Accuracy specifications
Accuracy: ± (a% reading + b digits), guarantee for 1 year.
Operating temperature: 23 ºC ± 5 ºC.
Relative humidity: <75%.
Temperature coefficient: 0,1 x (specified accuracy)/1ºC.
A.
DC Voltage
Range
200mV
2V
20V
200V
1000V
Remark:
• Input impedance: 10MΩ.
B.
AC Voltage
Range
2V
20V
200V
750V
32
All manuals and user guides at all-guides.com
Temperature
Battery Type
Data Holding
Overloading
Weight
Certificate
Resolution
0.01mV
0.0001V
0.001V
0.01V
0.1V
Resolution
0.0001V
0.001V
0.01V
0.1V
Updates 2~3 times/second
Operating: 0ºC~40ºC (32ºF~104ºF)
Storage: -10ºC~50ºC( 14ºF~122ºF)
≤75% @ 0ºC~30ºC
≤50% @ 31ºC~40ºC
2000m; Storage: 10000m.
9V NEDA1604 or 6F22 or 006P
Display "
Display " "
Display " "
Display "1"
165x80x38.3mm
Approx. 275g (battery included)
IEC61010 CAT II 1000V overvoltage and
double insulation standard
Accuracy
±(0.05%+3)
750V AC rms or Peak Value
±(0.1%+3)
Maximum tested DC voltage
±(0.15%+5)
Accuracy
±(0.5%+10)
750V AC rms or Peak Value
±(0.8%+15)
"
Overload Protection
250V DC or AC ms
1000Vp-p.
is 1000V.
Overload Protection
1000Vp-p.

Publicité

loading

Produits Connexes pour EGAmaster EGATRONIK

Ce manuel est également adapté pour:

51267