Sequential 8 12 VDC outputs : It has a double time scale selectable by means of Dip 6 (scale A or B), adjustable
time between 1 second and 100 minutes with 2 coarse-fine potentiometers, manual or automatic advance, inversion
of the relay advance direction. Pushbutton, Reset and Pause inputs.
Operation : When the sequential is powered, it connects and disconnects the relays sequentially, in automatic mode
according to the set time or manually when closing the INT input.
Closing the PAUSE input stops the advance of the relays, closing the RESET input disconnects all the relays.
POWER SUPPLY : Connect the 12 VDC power supply to the POWER terminal, respecting the ± polarity.
Install a fuse and switch for protection and safety, according to CE standard.
Before activating the switch, make all other circuit connections.
To power 230 V AC you can use our recommended power supplies FE-103 or FE-300.
8 sorties séquentielles 12 VDC : Elle dispose d'une double échelle de temps sélectionnable au moyen de Dip 6
(échelle A ou B), temps réglable entre 1 seconde et 100 minutes avec 2 potentiomètres coarse-fine, avance manuelle
ou automatique, inversion du sens d'avance du relais . Entrées Bouton-poussoir, Reset et Pause.
Fonctionnement : Lorsque le séquentiel est alimenté, il connecte et déconnecte les relais séquentiellement, en
mode automatique selon le temps paramétré ou manuellement lors de la fermeture de l'entrée INT.
La fermeture de l'entrée PAUSE arrête l'avance des relais, la fermeture de l'entrée RESET déconnecte tous les relais.
www.cebek.com
-
Sequential 8 outputs
Séquentielle 8 sorties
Secuencial 8 salidas
Seqüencial 8 sortides
I-55
Technical characteristics
Voltage : 12 V. DC.
Minimum/maximum Consumption : 20 mA / 70 mA.
Timing configuration scale A : 1 sec to 100 secs
Timing configuration scale B : 1 min to 100 mins.
Configuration outputs : 1 to 8 relays
Max. Output load : 7A ( 2A for inductive loads)
Operating Indicator Led : Relays , power DC
Protection against inversion polarity : Yes.
Dimensions : 107 x 155 x 22 mm.
Weight : 157 gr
Din rail : C7592
sat@fadisel.com

Publicité

loading

Sommaire des Matières pour CEBEK I-55

  • Page 1 Sequential 8 outputs Séquentielle 8 sorties Secuencial 8 salidas Seqüencial 8 sortides I-55 Technical characteristics Voltage : 12 V. DC. Minimum/maximum Consumption : 20 mA / 70 mA. Timing configuration scale A : 1 sec to 100 secs Timing configuration scale B : 1 min to 100 mins.
  • Page 2 I-55 ALIMENTATION : Connecter l'alimentation 12 VDC à la borne POWER en respectant la polarité ±. Installez un fusible et un interrupteur pour la protection et la sécurité, conformément à la norme CE. Avant d'activer l'interrupteur, effectuez toutes les autres connexions du circuit.
  • Page 3 I-55 PAUSE : Connect a button to the PAUSE input, closing the button stops the advance of the relays, opening continues the advance from the same relay where it stopped. RESET : Connect a button to the RESET input, when closing the button disconnects all the relays, opening the button starts the sequence from 0 or 8 depending on how the direction of advance is configured.
  • Page 4 I-55 AVANCE EN SENTIDO CRECIENTE O DECRECIENTE : Puede configurar el circuito para un avance creciente de Relé 1 a Relé 8 o decreciente de Relé 8 a  Relé 1 con el DIP 4 Dip 4 en OFF modo decreciente (del relé 8 al 1) Dip 4 en ON modo creciente (del relé...
  • Page 5 I-55 CONFIGURACIÓN NÚMERO SALIDAS : La selección del número de salidas de 1 a 8 se realizará con la combinación de los DIP 1 DIP 2 DIP 3, ver tabla. CONFIGURACIÓ NOMBRE SORTIDES : La selecció del nombre de sortides de 1 a 8 es realitzarà amb la combinació...
  • Page 6 I-55 CONNEXIÓ DE LA SORTIDA. CÀRREGA : Les sortides es realitzen mitjançant relés, dispositius aïllats elèctricament de la resta del circuit, que admeten qualsevol tipus de càrrega que no superi els 7 A. El relé disposa de tres terminals de sortida : el Comú, el Normalment obert en repòs (NO), i el Normalment tancat en repòs, (NC).
  • Page 7 I-55 www.cebek.com sat@fadisel.com...
  • Page 8 I-55 NOTA : This printed circuit is used for various models, it is normal for there to be free spaces. NOTA : Ce circuit imprimé est utilisé pour plusieurs modèles, il est normal qu'il y ait des espaces libres. NOTA : Este circuito impreso se emplea para varios modelos , es normal que hayan espacios libres .