Télécharger Imprimer la page

jbc ADVANCED Serie Mode D'emploi page 13

Masquer les pouces Voir aussi pour ADVANCED Serie:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ENGLISH
Change of desoldering tip
This operation should be done while the tip is hot,
at a minimum temperature of 250°C, so that any
tin left inside is in molten state.
- Unscrew the tip to be replaced, with the aid of
the spanner supplied.
- Fit the new tip, and tighten up with the spanner
to achieve a good air tightness.
Tip care
-
The largest rod that fits in the tip hole should
periodically be passed through in order to
clean the intake tube.
-
To clean the tips, use the sponge included
with the stand and check it is slightly moisted.
Only deionised water (car battery water)
should be used in order to wet the sponge.
If normal water was to be used, it is very likely
that the tip will become dirty due to the salts
dissolved within the water.
-
Do not file the tips or use abrasive tools
which may damage the tip's protective
surface coating and avoid knocking them
about.
-
If the tip has been a long time without being
tinned, use a metal brush to remove any dirt
and oxid.
All manuals and user guides at all-guides.com
IMPORTANT: DO NOT press the pushbutton
vacuum pump while tinning the desoldering tip,
as the fumes given off by the flux would quickly
soil the ducts and filter of the air circuit.
To empty the solder tin deposit and change
the filter
For this, the lid needs to be unscrewed and first
the tin deposit and then its spiral must be removed
to clean the inner part of the deposit with a brush.
-
-
Ref. 0780550
Solder tin deposits
It can be chosen between two different deposit
types:
-
-
12
The condition of the filter must be checked
and replaced if dirty or damaged.
The deposit needs to be inserted with spiral
filter put into place. Then the whole must be
closed by screwing the lid shut.
Filter Ref.0780840
Spiral
Deposit
Metal Ref. 0812630.
Glass Ref. 0812620.
L i d
Brush
Ref. 0786640

Publicité

loading

Ce manuel est également adapté pour:

Am 6000