Installation Procedure
Building roof of installation
0.5m (use white motor plug)
2.0m (use red motor plug)
Ceiling
Air supply
Note:
When connecting the short ducts, use the low static terminals, which color is white.
The distance L from the air outlet of the duct to the air outlet of the
When connecting the long ducts, use the middle static terminals, which color is red.
The distance L from the air outlet of the duct to the air outlet of the
The sketch map of long duct
Suspending hook
Drain pipe
Air return duct
Transition duct
Air return blind
1. Installation of air sending duct
This unit uses rounded duct, the diameter of the duct
is 180mm.
The rounded duct needs to add a transition duct to
connect with the air-sending duct of indoor unit, then
connect with respective separator. As Figure shown,
all the fan speed of any of the separator's air outlet
shall be adjusted approximately the same to meet
the requirement for the room air conditioner.
2. Installation of air return duct
Use rivet to connect the air return duct on the air
return inlet of the indoor unit, then connect the other
end with the air return blind as Figure shown.
3.Thermal insulation of duct
Air-sending duct and air return duct shall be thermally
insulated. First stick the gluey nail on the duct, then
attach the heat preservation cotton with a layer of
tinfoil paper and use the gluey nail cap to fix. Finally
use the tinfoil adhesive tape to seal the connected
part. As Figure shown.
A
Unit
Return air box
Return air
Air out duct
Tie-in of air
Air distributary
distributary
Air outlet grille
Air supply
There should
be no obstacles
within 1m
air
conditioner shall be no more than
air
conditioner shall be no more than
M8 wide expansion bolt
M8 suspender screw
M8 wide lock washer
M8 screw nut
Soft connection
Indoor unit
Transition duct Rounded duct
or static box
Air return blind
Air return duct
gluey nail
heat preservation cotton
22
Air Duct
Return air box
Unit
Return air
0.5
m.
2.0
m.
Air conditioner
Tie-in of air
distributary
Air distributary
Unit: mm
Indoor unit
rivet
tinfoil
gluey nail cap
adhesive tape