Télécharger Imprimer la page

GE Druck ADTS 405 R/F Mk2 Guide D'installation page 10

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 95
The test set performs a self-test, resulting in a test set system colour status
indication of either "READY", "NOT READY" or "FAULT".
The states of the main pressure control and pneumatic isolation valves
associated with protecting connected aircraft systems are presented on the
mimic panel (see Figure 6) both during and after self-test.
When status indicators Static Ground Vent (4) and Zero Ps/Pt cross vent (7)
are illuminated (Red) the test set is in the 'SAFE AT GROUND' state and the
external aircraft system may be safely connected or disconnected.
Note: If the self-test fails, or for any other reason the test set is considered to
be unserviceable, contact GE and return the test set to the GE or GE approved
service centre.
Power and self-test:
-
Pressure controller rack switched on (On)
-
Not Ready, self-test in progress (Orange)
-
Ready, self-test passed (Green)
-
Fault (Red)
5.
Dimensions
The ADTS 405F can be moved by use of the handles and wheels.
ADTS 405F
ADTS 405R
ADTS Remote
Hand
Terminal
[EN] English
CAUTION: THE ADTS 405F SHOULD BE LIFTED BY A MINIMUM
OF TWO PEOPLE.
Weight
29kg (64lb)
Height
442mm
Depth
332mm (front to rear)
Width
755mm (left to right)
Weight
12kg (26.5lb)
Height
6U
Depth
255mm (front to rear, behind mounting panel)
Width
19" Rack Mount
Weight
1kg (2.2lb)
Height
270mm
Depth
45mm
Width
125mm
6
124M8686 Revision A

Publicité

loading