MAINTENANCE

General

Glo-Ray
Heated Glass merchandisers are designed for
®
maximum
durability
and
maintenance.
WARNING
ELECTRIC SHOCK HAzARD:
• Turn OFF power switches, unplug power cords, and
allow unit to cool before performing any cleaning,
adjustments, or maintenance.
• This unit has two power cords. Disconnect BOTH
power
supply
cords
maintenance or cleaning.
• DO NOT submerge or saturate with water. Unit is not
waterproof. Do not operate if unit has been submerged
or saturated with water.
• Do not steam clean or use excessive water on unit.
• This unit is not "jet-proof" construction. Do not use jet-
clean spray to clean this unit.
• Do not clean unit when it is energized or hot.
This unit has no "user-serviceable" parts. If service is
required on this unit, contact an Authorized Hatco Service
Agent or contact the Hatco Service Department at
800-558-0607 or 414-671-6350; fax 800-690-2966; or
International fax 414-671-3976.
Use only Genuine Hatco Replacement Parts when service
is required. Failure to use Genuine Hatco Replacement
Parts may subject operators of the equipment to hazardous
electrical voltage, resulting in electrical shock or burn.
Genuine Hatco Replacement Parts are specified to operate
safely in the environments in which they are used. Some
aftermarket or generic replacement parts do not have the
characteristics that will allow them to operate safely in
Hatco equipment.

Daily Cleaning

To preserve the finish of the unit as well as maintain
performance, it is recommended that the unit be cleaned daily.
NOTICE
Use non-abrasive cleaners only. Abrasive cleaners could
scratch the finish of the unit, marring its appearance and
making it susceptible to soil accumulation.
1. Turn off the unit, unplug the power cords, and allow the
unit to cool.
2. Remove all food containers.
3. Wipe down the hardcoated heated base and all metal
surfaces using a clean, damp cloth. Stubborn stains may
be removed with a good non-abrasive cleaner. Hard to
reach areas should be cleaned with a small brush and mild
soap.
4. Clean the heated glass shelves and glass side panels
using ordinary glass cleaner and a soft cloth or paper
towel.
performance
with
minimum
before
performing

Ground Fault Circuit Interrupters

Heated Glass merchandisers are supplied with two, built-in
Ground Fault Circuit Interrupters (GFCI) — one for each circuit.
GFCIs are designed to turn off electrical power and help prevent
damage to the internal components when there is a short circuit
or electrical fault.
To reset a GFCI:
1. make sure the unit is plugged in and all ON/OFF switches
are in the ON position.
2. Push the red RESET button.
NOTE: The unit must be plugged in and turned on for the GFCI
any
to reset. If the unit is off, the GFCI will not reset.
If a GFCI continues to trip, contact an authorized Hatco Service
agency.
RESET Button
Ground Fault Circuit Interrupters

Replacing a Display Light

The unit is equipped with fluorescent lamps that illuminate the
warming area. These lamps have a special coating to guard
against injury and food contamination in the event of breakage.
Use Hatco P/N 02.30.134.00 when replacing a lamp.
Use only fluorescent lamps that meet or exceed National
Sanitation Foundation (NSF) standards and are specifically
designed for food holding areas. Breakage of fluorescent
lamps not specially protected could result in personal
injury and/or food contamination.
Use the following procedure to replace a fluorescent lamp.
1. Turn off the unit, unplug the power cords, and allow the unit
to cool.
2. Carefully twist the fluorescent lamp and pull down to
remove it from the sockets on each end.
3. align the tabs on each end of the new fluorescent lamp with
the channels on each socket, and push the lamp up into
the sockets.
4. Carefully twist the fluorescent lamp in the sockets until it
"snaps" into position.