General
To comply with the Canadian Electrical Code and the Canadian
Standards Association, the load center must be installed in accordance
with the information included on the label on the inside of the
equipment. A qualified electrical contractor or licensed electrician
must also do this in accordance with the applicable local electrical
codes and.
WARNING: Hazard of electrical shock or burn. Turn off power
supplying this equipment before working inside.
Installation
1 – Remove Front
Slip the front and accessory package back into the carton to protect
the finish.
2 – Remove Service Entrance Barrier (Main
Breaker only)
Back out and save the two mounting screws securing the service
entrance barrier over the main breaker connections, then lift the
barrier up and out.
Barrier
Mounting
Screws
DEH41005
Installation Instructions
PowerMark Gold ™ Load Centers
100–225 Ampere Single-Phase 12–42 Circuit, Indoor
Type
3 – Remove Interior (optional)
Back out mounting
screws and save for
reuse.
Slide interior up to
clear tabs and
remove.
4 – Mount Box
Flush mount: Line up the front box edge with
the finish wall surface and screw or nail to the
stud through the small knockouts in the box
side.
Surface mount: Screw or nail through the
keyhole slots in the back of the box.
Top or bottom feed
The load center will easily accommodate incoming electrical
service from the top or bottom. Rotate the entire load center
enclosure if a bottom feed configuration is required.
Nail or
Screw

Publicité

loading

Sommaire des Matières pour ABB PowerMark Gold DEH41005

  • Page 1 DEH41005 Installation Instructions PowerMark Gold ™ Load Centers 100–225 Ampere Single-Phase 12–42 Circuit, Indoor Type General 3 – Remove Interior (optional) To comply with the Canadian Electrical Code and the Canadian Standards Association, the load center must be installed in accordance with the information included on the label on the inside of the equipment.
  • Page 2 Neutral Terminal Bond Screw 5 – Remove Knockouts for All Main and Branch Circuits First drive the center knockout inward. The outer rings should then be alternately pried up or driven in one at a time. Drive the center knockout Insulated Ground inward, then the outer Or Neutral...
  • Page 3 16 – Lock out procedure : Shackle diameter of padlock must be .25’’to 0.30’’ If hasp is used jaw diameter for hasp must be 1.0 ’’ to 1.5’’ Please do not deform tab on the barrier Barrier Shackle Padlock Mounting screws These instructions do not cover all details or variations in equipment nor do they provide for every possible contingency that may be met in connection with installation, operation, or maintenance.
  • Page 4 DEH41005 Instructions d’installation Panneaux de Distribution PowerMark Gold™ 12 à 42 Circuits à phase simple de 100-225 Ampères Type pour l’intérieur Généralités 3 – Enlever l’interieur (facultatif) Pour nous conformer aux directives du Code canadien de l’électricité et à celles de l’Association canadienne de normalisation, le panneau de distribution doit être installé...
  • Page 5 5 – Enlever les déboucheres pour tous les circuits Neutre principauxet de dérivation Borne A Vis de Il faut premièrement frapper la débouchure centrale vers l’intérieur. fixation Les anneaux l’entourant doivent être soulevés ou enfoncés en alternance, un à la fois. Frapper la débouchure Mise à...
  • Page 6 Aux procédures de verrouillage Diamètre de manille de cadenas doit être. 25''to 0.30''. Si hasp est utilisé diamètre jaw pour hasp doit être de 1.0''à 1.5'' S'il vous plaît ne se déforment pas l'onglet sur la barrière Barriere Manille cadenas vis de montage General Electric Company...