Télécharger Imprimer la page

klover BF-01 Installation, Utilisation Et Entretien, Conseils Utiles page 73

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Display during the work phase
PELLET SIDE
WORK POWER SET
WATER
TEMPERATURE
IN BOILER
Functioning principle
The thermo stove can function just with pellets, just with wood or with both combustion chambers on.
There are two functioning conditions:
Pellet side conditions with PELL ON:
it switches on automatically when the wood side switches off:
it is switched on manually;
it switches on with the chrono-thermostat.
Pellet side conditions with PELL OFF:
it does not switch on automatically when the wood side switches off:
it is not switched on manually;
if set with pellet side running then when the pellet side switches off, it remains off;
it switches on with the chrono-thermostat.
ATTENTION: To set "Pell on" or "Pell off" press keys 5 or 6 and then choose the desired function with key 4, with the flashing words in the lower display .
Pellet functioning
Pellet only (functioning with 5 work powers, functioning economy phase, chrono-thermostat, room thermostat function active).
If the wood side is switched-on (wood fumes temperature ≥ Pr48) the pellet side switches off when the temperature set on the Set H2O is reached.
Wood functioning
Wood only;
With wood on, it is possible to switch the pellet side on manually, which will switch-off when the temperature set on the set H2O is reached. To switch
the pellet side on, hold key 4 down (switch-on/off);
With "Pell on" function active:
o
The pellet side switches on when the wood side switches off i.e. when the temperature of the fumes is lower than 150°C (Pr48) and the temperature
of the water in the boiler is lower than 60°C (Pr11).
With "Pell off" function active:
o
The pellet side DOES NOT switch on when the wood side switches off i.e. when the temperature of the fumes is lower than 150°C (Pr48) and the
temperature of the water in the boiler is lower than 60°C (Pr11).
With the wood side on, the pellet side switches off immediately on reaching the temperature set on the SET H2O.
With the wood side off, the pellet side switches off only if, after having reached the ECO H2O, it exceeds the temperature differential set on the Pr12 or
pass the ECO H2O time set on Pr23.
Functioning with room environment
The room thermostat has the function of switching the pump off and therefore to send the thermo stove into "Eco tOFF" functioning economy when the
contact is open.
The room thermostat function can only intervene on the pellet side (controlled combustion). If the wood side should be on, the room thermostat function is
excluded.
Ignition of the thermo stove (WOOD SIDE)
Perform the following operations:
Before switching the thermo stove on, make sure that the control unit switch is on;
Make sure there is water in the system and inside the boiler body;
Open the wood side combustion regulator completely (it is advised also to open the hatch under the wood side);
Light the fire using seasoned, thin wood, if possible;
After the wood has ignited sufficiently, regulate the combustion air using the wood side combustion regulator (and, if open, close the hatch under the
wood side);
THE FIRE BOX MUST BE KEPT CLOSED EXCEPT DURING RELOADING IN ORDER TO PREVENT SMOKE FROM ESCAPING.
NEVER IGNITE THE THERMO STOVE USING ALCOHOL OR OTHER HIGHLY INFLAMMABLE LIQUIDS.
All manuals and user guides at all-guides.com
13
WOOD SIDE
INDICATOR ON

Publicité

loading

Ce manuel est également adapté pour:

Bi-fire