CLEANING THE DRAIN PUMP FILTER
The pump filter can filter the yarns and small foreign matters from the washing. Especially after washing
fleecy, woolly or very old laundry.
WARNING!
• Unplug the appliance to avoid electrical shock before cleaning.
• Be careful of hot water!
• Allow detergent solution to cool down.
• During cleaning, some water may be spilled. It is recommended to place an absorbent cloth on the floor.
1
Open the pump filter cap.
4
Open the pump filter by turning
it counter clockwise. Clean the
pump filter under running water.
WARNING!
• Never remove the pump filter cap during a washing cycle. Always wait until the appliance has finished the cycle,
and is empty.
• When the appliance is in use and depending on the selected program, there can be hot water in the pump.
• When replacing the pump filter cap, ensure it is securely snapped in place.
OPENING THE DOOR MANUALLY IN CASE OF A POWER OUTAGE ­ IN CASE OF A PROGRAM PAUSE
In case of a power outage during a washing cycle, the program will resume after the power is restored in most
cases. If not, you can manually open the door and remove the laundry.
WARNING!
• If there is still water in the appliance after a power outage, make sure not to open the door before you
manually drain the water from the appliance via the pump filter (see the paragraph CLEANING THE DRAIN
PUMP FILTER).
1. When the program is paused or interrupted, open the pump filter cap.
2. The door of the appliance can only be opened by simultaneously pulling the special lever - next to the
filter -and the door handle.
3. Open the door manually by pulling the handle towards you.
• TROUBLE SHOOTING
The appliance will automatically control the operation of particular functions during the washing cycle. If any
irregularity occurs, this will be identified by reporting (E:XX) on the display. The appliance will report the error
until it is switched off. Disturbances from the environment (e.g. the power grid) may result in various error
reports. In such case:
2
Turn 90°, pull out the emergy
discharge hose and remove
the cap.
5
Remove any objects and
impurities from the filter
housing.
3
When there's no more water
coming out, put the emergy
discharge hose back.
6
Place the pump filter back
and turn it clockwise to lock it.
Close the pump filter cap.