Service instructions
Service instructions
Service instructions
The information in this chapter is intended to show the main steps to be taken
when servicing the tool. For detailed information on the included parts, see the
exploded views/tables.
General information
Recommended interval between actions:
(Valid at normal usage of the tool at a load up to 70% of maximum torque.)
• Exchange front part after approximately 1.000.000 cycles.
• Exchange drive unit after approximately 5.000.000 cycles.
• Calibrate the tool after 1.000.000 cycles or after 1 year.
Service conditions:
• The complete system needs to be available when a repair or calibration is to
be done.
Service equipment:
• Normal workshop equipment.
• Necessary special equipment as shown in the exploded views/tables.
• For testing a calibration rig is recommended.
• PC with internet connection to be able to download necessary keys.
Preventing ESD problems
The components inside the tool and controller are sensitive to electrostatic dis-
charge. To avoid future malfunction, make sure that service and maintenance is
carried out in an ESD approved work environment. The figure below shows an
example of an appropriate service work station.