Télécharger Imprimer la page

Wittur servogearless eco WSG-S1.2 Instructions De Service page 92

Moteur d'ascenseur sans engrenage

Publicité

Troubleshooting and fault elimination
Fault
Brake does not release
Rotor cannot rotate freely
Rotor thickness too small
Voltage is not zero during
the functional test
(
36)
Voltage too high
Voltage too low
AC voltage is not mains
voltage
INTORQ | BA 14.0197 | 04/2016
Cause
Microswitch incorrectly wired
Microswitch incorrectly set
Air gap too big
Wrong setting of manual
release
Air gap "s
" too small
L
Rotor has not been replaced
in time
Microswitch incorrectly wired
Microswitch defective or
incorrectly set
Brake voltage does not match
the rectifier
Brake voltage does not match
the rectifier
Fuse is missing or defective
Microswitch incorrectly wired
Microswitch defective or
incorrectly set
Remedy
Check the wiring of the microswitch and correct it.
Replace the complete stator and make a complaint about
the setting of the microswitch to the manufacturer.
Adjust the air gap (
27)
Measure the rotor thickness and compare against the min-
imum rotor thickness (
rotor.
Check the dimension "s+s
dimension must be the same on both sides. Correct if
required.
Check air gap "s
" and adjust it if necessary (
L
Replace the rotor (
43).
Check and correct the wiring of the microswitch.
Replace the complete stator and send the complete
stator to the manufacturer.
Adjust rectifier and brake voltage to each other.
Adjust rectifier and brake voltage to each other.
Select a connection with proper fusing.
Check and correct the wiring of the microswitch.
Replace the complete stator and return the defective com-
plete stator to the manufacturer.
16). If required, replace the
" with the brake energised. The
L
27).
47

Publicité

loading

Ce manuel est également adapté pour:

Servogearless eco wsg-s1.3