Safety Information (continued)
ELEcTRIcAL cONNEcTION
A 15-Amp, 120-Volt, 60 Hz circuit with a properly grounded outlet is required. Preferably, the item will be on a dedi-
cated circuit as other appliances on the same circuit may cause the circuit breaker to trip or the fuse to blow when
the heater is in operation. The unit comes standard with a 6 ft. (1.8 m) long three wire cord, exiting the right side of
the item. Always plug the unit into a wall outlet/receptacle. An extension cord or re-locatable power tap, (outlet/power
strip), should never be used.
Electrical outlet wiring must comply with local building codes and other
applicable regulations to reduce the risk of fire, electrical shock and injury
to persons.
Do not use this item if any part of it has been under water. Immediately
call a qualified service technician to inspect the item and replace any part
of the electrical system which has been under water.
GROUNDING INSTRUcTIONS
This heater is for use on 120 volts. The cord has a plug as shown at (A) in Figure 1. An adapter as shown at (C) is avail-
able for connecting three-blade grounding-type plugs to two-slot receptacles. The green grounding lug extending from the
adapter must be connected to a permanent ground such as a properly grounded outlet box. The adapter should not be used
if a three-slot grounded receptacle is available.
GROUNDING
PIN
(C)
Figure 1
(A)
METAL SCREW
COVER OF GROUNDED
ADAPTER
GROUNDING
MEANS
GROUNDING
PIN
DANGER
OUTLET BOX
(B)
(D)
4
NOTE:
Adapters are NOT
for use in Canada.