GENERAL INSTRUCTIONS
Carefully read and follow instructions.
Use the unit only in ambient air temperatures of 35–100° F
(2–38° C) and water temperatures of 35–100°F (2–38° C).
This installation must comply with all applicable state and local
regulations.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system.
Do not expose the unit to direct sunlight or use this unit outdoors.
Do not use electrical heating tape on this unit.
Do not use pipe compound ("pipe dope"), sticks, or similar com-
pounds with this unit; they contain petroleum derivatives which will
cause crazing and cracking of the plastic in the filter.
Do not use aerosol sprays (bug spray, cleaning fluids, etc.) near the
filter; they contain organic solvents which will cause crazing and
cracking of the plastic in the filter.
Use only teflon tape without adhesive backing to seal joints.
Use only soap and water to clean filter housing and
components.
Change the cartridge every 3 months (or more often if you notice a
sustained drop in water pressure or a change in the taste of the
water). Follow the "Procedure For Cartridge Change" (Page 2) when
changing cartridges. Use only OMNIFILTER replacement
cartridges.
The fittings included with this unit allow for installation with 3/4"
copper pipe. If your plumbing is NOT 3/4" copper (for example, if it
is galvanized), additional fittings are required.
Install the unit vertically (with cartridge tank pointing down) ahead
of the hot water heater. Allow 3" clearance below the cartridge
tank to allow for changing the cartridge.
DO NOT use a torch near the unit.
This unit is designed for non-commercial use on cold water lines only.
Wear safety glasses during installation.
This unit is not designed to filter sulfur (rotten egg odor) and its use
with sulfur may intensify taste and odor problems.
Risk of electrical shock. If your water pipes are
used to ground your house's electrical system, install a No. 8
) jumper wire (or larger) around the filter (see
AWG (8.4mm
2
Figure 1). The jumper wire must be connected at both ends by
a pressure wire fitting or other connection that satisfies NEC
or CEC and local codes. Consult a building inspector or licensed
electrician for more information.
System Tested and Certified by NSF International
against ANSI/NSF Standard 42 for Chlorine Reduction,
Class III, and Particulate Reduction, Class I.
This NSF certification applies only to the U25 filter with
the T01 Cartridge.
©2000, Omnifilter
All manuals and user guides at all-guides.com
®
6.5" (Copper) or 8" (Galvanized)
3624 1199
3626 1199
Figure 2
Whole House Filter
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
Tools and Fittings Needed:
For Installation with Copper Pipe:
• Tubing cutter (preferred) or hacksaw to cut into pipes
• 10" Adjustable wrench or 1-1/4" open end wrench to tighten
locknuts
For Installation with Galvanized Pipe:
• 1 Union plus a 2" Nipple
• Pipe cutter or hacksaw to cut into pipes
• Pipe wrenches to tighten union and nipple
• Pipe threader (some hardware stores will thread pipe for you at
purchase – one approach would be to remove one section of pipe
and purchase two sections for reinstallation that, together, meas-
ure 8" shorter than the piece you removed.)
• Paint thinner or solvent (NOT gasoline) to clean new threads
• Teflon tape without adhesive backing for sealing joints.
All Installations
1. Turn off the main water supply valve and open a faucet to drain
the system.
2. Cut out the template (located on the bottom of Page 2) that
matches your system's piping.
3. Place the template on the pipe and cut the pipe as shown in
Figure 2.
4. Copper pipe: Go to Step 5 under "Installation on 3/4" Copper
Pipe".
Galvanized pipe: Go to Step 5 under "Installation on
Galvanized Pipe".
Installation on 3/4" Copper Pipe:
5. Place the lock nuts on the pipe, small end first. Follow the lock
nuts with the brass compression sleeves (one for each cut pipe
end). Slide each brass compression sleeve up 1/4" from the cut
end of the pipe (see Figure 3).
6. Thread the brass compression fittings into the ports in the hous-
ing. Be sure that the red Vibra-Seal end of the fitting goes into
the port. Tighten the compression fittings with the 1-1/4"
wrench until they are snug. DO NOT OVERTIGHTEN.
7. Place the filter (with its fittings) in position on the pipe. Be sure
that the port marked "IN" is on the side toward the water meter
so that the flow enters the filter through this port.
8. Insert the copper pipe into the left-hand compression fitting,
making sure that the copper pipe bottoms out inside the fitting.
Tighten the left-hand lock nut securely with the wrench. Hold the
fitting with a wrench to prevent overtightening it in the housing.
9. Repeat Step 8 with the right hand compression fitting, sleeve,
and nut. Skip to Step 10 under "All Installations", Page 2.
Installation on Galvanized Pipe:
5. Thread the cut pipe ends and clean all traces of cutting oil, rust,
hardened pipe compound, etc., from all threads that will be
Printed in U.S.A.
Model U25
1/4"
Compression
Sleeve
Lock Nut
3625 1199
Figure 3
51330 (Rev. 4/4/00)

Publicité

loading

Sommaire des Matières pour Omnifilter U25

  • Page 1 ANSI/NSF Standard 42 for Chlorine Reduction, Installation on Galvanized Pipe: Class III, and Particulate Reduction, Class I. This NSF certification applies only to the U25 filter with 5. Thread the cut pipe ends and clean all traces of cutting oil, rust, the T01 Cartridge.
  • Page 2 Cartridges containing cellulose may seem to disintegrate, produce a “sewer” or “rotten egg” odor, or form a black precipitate due to bac- teria. If this happens, consult OMNIFILTER Customer Service for advice. PROCEDURE FOR CARTRIDGE CHANGE 1. Place a pan under the unit to catch any spilled water.
  • Page 3 Classe I. filets à visser sur le filtre. Nettoyer les filets de chaque extrémité du tuyau Cette homologation, par la NSF, ne s'applique qu'au filtre U25 avec du diluant ou du solvant à peinture (PAS d'essence); les essuyer et les...
  • Page 4 9. Ouvrir un robinet et laisser couler l'eau pendant au moins 3 minutes de façon à pouvoir chasser toute accumulation d'air, de fines, etc. NOTA : Pour obtenir le meilleur résultat possible, n'utiliser que des cartouches de rechange d'origine OMNIFILTER. Ne pas utiliser de cartouches de rechange OMNIFILTER annulera la garantie. Circulation Water Flow NOTA : La cuve du filtre a une durée limitée.
  • Page 5 "Procedimiento para Cambiar el Cartucho" (Página 6) cuando cambie los car- 3. Coloque la plantilla en el tubo y corte el tubo según se ilustra en la tuchos. Use solamente cartuchos OMNIFILTER de repuesto. figura 2. 4. Tubo de cobre: Vaya al Paso 5 de la "Instalación en Tubería de Cobre de Los accesorios incluidos con esta unidad se adaptan a instalaciones con 3/4"...
  • Page 6 9. Abra un grifo durante unos 3 minutos para permitir que salga toda acu- de agua Water Flow mulación de aire, finos, etc. AVISO: Use solamente cartuchos de repuesto genuinos OMNIFILTER para obtener mejores resultados. Si no se usan filtros de repuesto OMNIFILTER, la Niple de 2" garantía quedará anulada. 2" Nipple Unión Union AVISO: El tanque del filtro tiene una vida útil limitada.