5.1.2 Danfoss RA adapter
The provided adapter is required to attach to Danfoss RA valves. If
necessary, use a screwdriver to slightly bend open the adapter (see
following figure).
The Danfoss valve bodies have elongated notches (1) around their
circumference, which ensure that the adapter is properly seated
when it snaps on.
During installation, please ensure that the pins inside the
adapter (2) are lined up with the notches (1) on the valve.
Ensure that a suitable adapter for the valve is properly
clipped on.
Please ensure that you do not trap your fingers between the
two halves of the adapter!
After clipping onto the valve body, please attach the adapter using
the provided screw and nut.