Télécharger Imprimer la page

Panasonic WV-CP230 Manuel D'utilisation page 2

Publicité

Les langues disponibles

Les langues disponibles

CONNECTIONS
A. WV-CP230 (220 - 240 V AC 50 Hz)
Connect the power cord to an electrical outlet
of 220 - 240 V AC 50 Hz.
B. WV-CP232 (12 V DC)
Connect the power cord to the DC 12 V IN
terminal on the rear panel of the WV-CP232.
@ !
12 V DC
(10.5 V - 16 V)
Resistance of copper wire [at 20°C (68°F)]
Copper wire
#24
#22
#20
size (AWG)
(0.22mm
2
)
(0.33mm
2
)
(0.52mm
2
)
(0.83mm
Resistance
0.078
0.050
0.030
Ω/m
Resistance
0.026
0.017
0.010
Ω/ft
• Calculation of maximum cable length bet-
ween camera and power supply :
10.5 V DC ≤ V
− (R x 0.42 x L) ≤ 16 V DC
A
L : Cable length (meters)
R : Resistance of copper wire (Ω/meter)
V
: DC output voltage of power supply unit
A
− 12
V
A
L standard =
(meters)
0.42 x R
− 16
V
A
L minimum =
(meters)
0.42 x R
− 10.5
V
A
L maximum =
(meters)
0.42 x R
C. WV-CP234 (24 V AC 50 Hz)
Connect the power cable to the AC 24 V IN
terminal on the rear panel of the WV-CP234.
1
2
24 V AC, 50 Hz
(19.5 V - 28 V)
Recommended wire gauge sizes for 24 V AC line
Copper wire
#24
#22
#20
size (AWG)
(0.22mm
2
)
(0.33mm
2
)
(0.52mm
2
)
(0.83mm
(m)
95
150
255
Length
of Cable
(Approx.)
(ft)
314
495
842
FOCUS OR FLANGE-BACK ADJUSTMENT
The following adjustment should be made by
qualified service personnel or system installers.
q Loosen the screws on the flange-back adjust-
ing ring.
w
Flange-back
q e
Adjusting Ring
Screws
All manuals and user guides at all-guides.com
Installation of Auto Iris Lens
Connector
Install the lens connector (YFE4191J100) when
using a video drive ALC lens.
The installation should be made by qualified
service personnel or system installers.
Cut the iris control cable at the edge of the lens
connector to remove the existing lens connector
and then remove the outer cable cover of the sup-
plied connector as shown in the diagram.
The pin assignment of the lens connector is as fol-
lows:
Pin 1: Power source; +9 V DC, 50 mA max.
Pin 2: Not used
Pin 3: Video signal; 1.3 V[p-p]/40 kΩ
Pin 4: Shield, ground
Rib
Pin 3
Pin 1
Pin 4
#18
Pin 2
2
)
0.018
Solder the lens cable to the pins of the sup-
plied connector.
0.006
Mounting the Lens
Caution:
Before you mount the lens, loosen the two
screws on the ring, and rotate this ring clock-
wise until it stops. If the ring is not at the end,
the inner glass or CCD image sensor may be
damaged.
q Mount the lens by turning it clockwise on the
lens mount of the camera.
w Connect the lens cable to the auto iris lens
connector on the side of the camera.
w
Flange-back
Adjusting Ring
Caution for Mounting the Lens
The lens mount should be a C-mount or CS-mount
(1"-32UN) and the lens weight should be less than
g (0.99 lbs). If the lens is heavier, both the
450
lens and camera should be secured by using the
#18
supporter.
2
)
The protrusion at the rear of the lens should be as
425
shown in the diagram.
1 403
C-mount: Less than 13 mm (1/2")
CS-mount: Less than 8 mm (5/16")
w Turn the flange-back adjusting ring to the
desired position.
Caution: When the C-mount lens is mounted,
do not rotate the ring counterclockwise
by force after it stops. If the ring is rotat-
ed by force, the inner lens or CCD image
sensor may be damaged.
e Tighten the screws on the flange-back adjust-
ing ring.
SPECIFICATIONS
Pick-up Device:
Scanning Area:
Synchronization:
Scanning System:
Scanning:
Horizontal:
Vertical:
Horizontal Resolution:
Video Output:
Signal-to-Noise Ratio:
Electronic Light Control:
Minimum Illumination:
Detail:
Lens Mount:
Ambient Operating Temperature:
Ambient Operating Humidity:
Power Source and
Power Consumption:
Dimensions (without lens):
Weights (without lens):
Weights and dimensions indicated are approximate.
Specifications are subject to change without notice.
STANDARD ACCESSORIES
Body Cap............................................................................................1 pc.
ALC Lens Connector (YFE4191J100).................................................1 pc.
Screws
q
OPTIONAL ACCESSORIES
Lenses: WV-LA2R8C3B, WV-LA4R5C3B, WV-LA9C3B, WV-LA210C3, WV-LA408C3, WV-LA908C3,
WV-LZ61/10, WV-LZ62/2, WV-LZ62/8, WV-LF4R5C3A, WV-LF9C3A, WV-LFY3C3,
WV-LFY45C3, WV-LFY9C3
752 (H) x 582 (V) pixels, Interline Transfer CCD
4.89 (H) x 3.67 (V) mm (Equivalent to scanning area of 1/3"
pick-up tube)
Internal, Line-locked or Multiplexed vertical drive (VD2)
selectable
2 : 1 interlace
625 lines / 50 fields / 25 frames
15.625 kHz
50 Hz
480 lines
1.0 V[p-p] PAL composite 75 Ω / BNC connector
50 dB (AGC OFF, weight ON)
Equivalent to continuous variable shutter speed between 1/50 s
and 1/15 000 s
0.6 lx (0.06 foot-candle) at F0.75 [equivalent to 2.0 lx (0.2 foot-
candle) at F1.4] AGC ON
SHARP or SOFT, selectable
C-mount or CS-mount, selectable
−10°C - +50°C (14°F - 122°F)
Less than 90 %
WV-CP230:
220 - 240 V AC 50 Hz, 3.9 W
WV-CP232:
12 V DC, 270 mA
WV-CP234:
24 V AC 50 Hz, 3.7 W
67 (W) x 65 (H) x 123 (D) mm
[2-5/8" (W) x 2-9/16" (H) x 4-13/16" (D)]
0.62 kg (1.37 lbs)
WV-CP230:
WV-CP232:
0.4 kg (0.88 lbs)
WV-CP234:
0.43 kg (0.95 lbs)
Matsushita Electric Industrial Co., Ltd.
Central P.O. Box 288, Osaka 530-91, Japan

Publicité