DECORATIVE
VENTILATION FAN WITH LIGHT
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at
the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a
tag, to the service panel.
3. Installation work and electrical wiring must be done by
a qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction
codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not dam-
age electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. NEVER place a switch where it can be reached from a
tub or shower.
8. This unit must be grounded.
9. This unit is U.L. listed. Type I.C. inherently protected.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. This product is designed for installation in FLAT CEILINGS
ONLY. Do not mount this product in a wall.
3. The light fixture assembly must be mounted to the fan
housing assembly included with this product. Do not
mount the light fixture assembly to a wiring outlet box.
4. To avoid motor bearing damage and noisy and/or unbal-
anced impellers, keep drywall spray, construction dust,
etc. off power unit.
5. Please read specification label on product for further
information and requirements.
Installer:
Leave this manual with the
homeowner.
Homeowner:
Use and Care information on page 4.
All manuals and user guides at all-guides.com
TYPICAL INSTALLATIONS
HOUSING MOUNTED
DIRECTLY TO JOIST
Discharge parallel to joists.
HOUSING MOUNTED
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
*
Additional framing must be a 2x6 (minimum height), at least 9-inches long.
PLAN THE INSTALLATION
The unit will operate
most quietly and
efficiently when
located where the
shortest possible
duct run and
minimum number
of elbows will be
needed.
Use a roof cap or
wall cap that has a
built-in damper to
reduce backdrafts.
Plan to supply the
unit with proper
line voltage and
appropriate power
cable.
2x6 (or larger)
*
TO "I" JOIST
INSULATION
(Can be placed
around and over
fan housing.)
FAN
HOUSING
4-IN.
ROUND
DUCT
*
Purchase
separately
MODEL 768CHNT
Page 1
POWER CABLE
ADDITIONAL
MOUNTING
FRAMING
TABS
2 x 4
CEILING
JOIST or
TRUSS
HOUSING
CEILING
MATERIAL
GLASS
LIGHT SHADE
HOUSING MOUNTED
TO 2x4 TRUSS
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
SUSPENDED CEILINGS
Housing hung with wires -
3-point mount.
ROOF
CAP
*
4-IN. ROUND
*
ELBOW(S)
WALL CAP
*
2 x 4
CEILING
JOIST or
TRUSS
GRILLE
PAN
*
*

Publicité

loading

Sommaire des Matières pour NuTone 768CHNT

  • Page 1 All manuals and user guides at all-guides.com MODEL 768CHNT Page 1 DECORATIVE VENTILATION FAN WITH LIGHT READ AND SAVE THESE INSTRUCTIONS TYPICAL INSTALLATIONS WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR POWER CABLE ADDITIONAL INJURY TO PERSONS, OBSERVE THE FOLLOWING:...
  • Page 2 All manuals and user guides at all-guides.com MODEL 768CHNT Page 2 INSTALL THE HOUSING INSTALL THE HOUSING (continued) - PLEASE NOTE - THE FOLLOWING INSTALLATION ILLUSTRATIONS New Construction SHOW 2 X 6 JOISTS. IF YOU HAVE A TRUSS OR “I”- JOIST INSTALLATION, MOUNT THE VENTILATOR TO THE ADDITIONAL FRAMING IN THE SAME MANNER.
  • Page 3 All manuals and user guides at all-guides.com MODEL 768CHNT Page 3 INSTALL THE HOUSING CONNECT THE WIRING (continued) SCHEMATIC WIRING DIAGRAM L I G H T R E D B L U W H T L I G H T...
  • Page 4 BROAN-NUTONE ONE YEAR LIMITED WARRANTY Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of origi- nal purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
  • Page 5 All manuals and user guides at all-guides.com MODÈLE 768CHNT Page 5 VENTILATEUR DÉCORATIF AVEC LA LUMIÈRE VEUILLEZ LIRE CES DIRECTIVES ET LES CONSERVER INSTALLATIONS TYPES AVERTISSEMENT OBSERVEZ LES DIRECTIVES CI-DESSOUS DE MANIÈRE À RÉDUIRE LES RISQUES D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES CORPORELLES : 1. N’utilisez cet appareil que de la manière prévue par le fabricant.
  • Page 6 All manuals and user guides at all-guides.com MODÈLE 768CHNT Page 6 INSTALLATION DU BOÎTIER INSTALLATION DU BOÎTIER (suite) - VEUILLEZ NOTER - LES ILLUSTRATIONS SUIVANTES MONTRENT Construction neuve UNE INSTALLATION SUR DES SOLIVES DE 2 X 6. SI L’INSTALLATION EST FAITE SUR DES FERMES OU DES POUTRES EN «...
  • Page 7 All manuals and user guides at all-guides.com MODÈLE 768CHNT Page 7 INSTALLATION DU BOÎTIER RACCORD DU CÂBLAGE (suite) SCHÉMA DE CÂBLAGE I N T E R R U P T E U R R O U G E B L E U B L A N C L U M .
  • Page 8 GARANTIE LIMITÉE D’UN AN BROAN-NUTONE Broan-NuTone garantit à l’acheteur original que les produits vendus en vertu de la présente sont libres de tout vice de matériau ou de fabrication pour une période d’un an à compter de la date d’achat originale.
  • Page 9 All manuals and user guides at all-guides.com MODELO 768CHNT Página 9 VENTILADOR DECORATIVA CON LA LUZ LEA Y CONSERVE ESTAS INSTRUCCIONES INSTALACIONES TÍPICAS ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRICA O LESIONES PERSONALES, OBSERVE LO SIGUIENTE: 1. Utilice esta unidad solamente de acuerdo con las instrucciones del fabricante. Si tiene preguntas comuníquese con el fabricante...
  • Page 10 All manuals and user guides at all-guides.com MODELO 768CHNT Página 10 INSTALACIÓN DE LA CUBIERTA INSTALACIÓN DE LA CUBIERTA (continuación) - POR FAVOR NOTE - LAS SIGUIENTES ILUSTRACIONES DE LA INSTALACIÓN MUESTRAN VIGUETAS DE 2 X 6. SI LA INSTALACIÓN ES EN UNA VIGA O EN Construcción nueva...
  • Page 11 All manuals and user guides at all-guides.com MODELO 768CHNT Página 11 CONEXIÓN ELÉCTRICA INSTALACIÓN DE LA CUBIERTA (continuación) DIAGRAMA ELÉCTRICO Construcción existente C O M M . R O J O A Z U L B L A N C O L A M P .
  • Page 12 Esta garantía le da derechos legales específicos, y usted puede tener otros derechos que varían de estado a estado. Esta garantía reemplaza todas las garantías anteriores. Para calificar para servicio bajo esta garantía, usted debe (a) notificar a Broan-NuTone en la dirección o al teléfono abajo, (b) dar el número de modelo y la identificación de pieza y (c) describir el defecto en el producto o pieza.