Télécharger Imprimer la page

LG LCE3010SB.ABKLLGA Manuel Du Propriétaire page 20

Table de cuisson vitrocéramique à éléments radiants

Publicité

Les langues disponibles

Les langues disponibles

I N S TA L L AT I O N I N S T RU C T I O N S
PreParinG tHe inStaLLation Location
IMPORTANT INSTALLATION
INFORMATION
• All electric cooktops run off a single phase,
three-wire or four-wire cable, 240/208 volt, 60
hertz, AC-only electrical supply with ground.
• Minimum distance between cooktop and
overhead cabinetry is 30" (762 mm).
LCE3010SB Radiant Cooktop
Unit
A
Inch
30-27/32 21-15/32
mm
783
All dimensions are stated in inches and millimeters (mm).
Allow 2" (50 mm) space below the armored cable opening to clear the electric cable and allow
space for installation of the junction box on the wall at the back of the cooktop.
20
** Do not obstruct these areas!
30" Min.
(762 mm)
B
C
D
E
3-3/4
28-13/16 19-5/8 29-3/8 20-1/4
545
95
732
498
• Make sure the cabinets and wall coverings
around the cooktop can withstand the
temperatures (up to 93°C [200°F]) generated
by the cooktop.
30 inch Radiant Cooktop
4" X 8" (102 mm x 203 mm)
opening to route armored
cable if panel is present.
F
G
I
H
Min
Min
Max
13/16
13
746
515
20
330
J
K
L
Min
5-23/32
2-1/2
24
145
64
610

Publicité

loading

Ce manuel est également adapté pour:

Lce3610sbLce3010sbLce3610sb.abkllgaLce3010sb-sd25-3398