Dimensions and weights of radiators
Power(W)
Width (mm)
Thickness (mm)
Height (mm)
Weight (kg)
1.4 - Connect the radiator
The radiator must be powered at 230V 50 Hz.
The radiator power supply must be connected directly to the network behind the omni-pole
breaking device with a contact opening distance of at least 3 mm without an intermediate
switch (clock, mechanical and static relay, ambience thermostat, etc).
The connection to the mains power supply will be made using a 3-wire cable (Brown =
Phase, Blue = Neutral, Black = Pilot wire) through a connection box. The connection box
must be installed at least 25 cm above the floor in wet rooms like kitchens, the bathrooms.
The installation must be provided with a circuit breaker type protection device.
Connection to the earth is prohibited. Do not connect the pilot wire (black) to the earth.
The manufacturer, his after sales service or a similar qualified person must replace the
power supply cable if it is damaged, so that the work can be done safely.
The power supply cable must be put back into position and fixed with the plastic
flange to hold the thermostat in position. There is a risk of electrical danger if this
operation is not respected.
If the pilot or piloted radiator is protected by a 30mA differential protection device (e.g.
bathroom), then the power supply to the pilot wire connected onto this differential switch
will have to be protected.
Pilot wire connection test
You can connect the pilot wire if your house is fitted with a programming unit, or a power
manager.
User's manual
Horizontal model
750
1000
1250
487
635
783
145
607
15
21
27
1500
2000
1000
931
1153
1161
30
40
26,2
Vertical model
1500
2000
458
150
1383
1605
28,4
38
53