• If the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
• Always use proper terminals, switch position, and range for measurements.
• To reduce the risk of fire or electric shock, do not use this product around
explosive gas or in damp locations.
• Verify the Meter operation by measuring a known voltage.
If in doubt, have the Meter serviced.
• Do not apply more than the rated voltage, as marked on Meter, between
terminals or between any terminal and earth ground.
• Avoid working alone so assistance can be rendered.
• Do not use the Tester if the Tester is not operating properly or if it is wet.
• Individual protective device must be used if hazardous live parts in the
installation where the measurement is to be carried out could be accessible.
• Use caution with voltages above 30 Vac rms, 42 Vac peak, or 60 Vdc.
These voltages pose a shock hazard.
• DO NOT USE the test leads when the internal white insulation layer is exposed
• DO NOT USE the test leads above maximum ratings of CAT. environment,
voltage and current, that are indicated on the probe and the probe tip guard cap.
• DO NOT USE the test leads without the probe tip guard cap in CAT III and CAT
IV environments.
• Probe assemblies to be used for MAINS measurements shall be RATED as
appropriate for MEASUREMENT CATEGORY III or IV according to IEC 61010
-031 and shall have a voltage RATING of at least the voltage of the circuit to be
measured.
• Disconnect circuit power and discharge all high-voltage capacitors before
testing resistance, continuity.
Symbols as marked on the Meter and Instruction manual
Risk of electric shock
DC measurement
Both direct and alternating
current
Battery
Conforms to EU directives
Do not discard this product or throw away.
Maintenance
Do not attempt to repair this Meter. It contains no user serviceable parts.
Repair or servicing should only be performed by qualified personnel.
CAUTION
• When connecting the test leads to the DUT (Device Under Test) connect the
common test leads before connecting the live test leads ; when removing the
test leads, remove the live test leads before removing the common test leads.
• Make sure that the buzzer sound is perceptible before using it under high
background noise environment.
EN
See instruction manual
!
AC measurement
Equipment protected by double
or reinforced insulation
Earth
Application around and removal
from hazardous live conductors
is permitted