Dometic PLB 40 Notice D'utilisation page 15

Masquer les pouces Voir aussi pour PLB 40:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PLB40
Problem
The display shows the warn-
ing symbol and the charge
arrow symbol flashes with
audible alarm and stops after
30 seconds (5 –8 V±1).
No charge arrow is shown
(under 5 V).
The display shows the warn-
ing symbol. The discharge
arrow and either the USB or
2-pin or DC symbol flashes.
An error sound is beeping for
60 seconds.
The battery symbol is flash-
ing. An error sound beeps
every 3 seconds for 10 times.
After the beeps the device
switches off automatically.
The battery does not give out
current (without active turn-
ing on the device).
The letters and symbols on
the display are fading.
EN
Cause
The input voltage of the char-
ger is wrong.
The input voltage of the char-
ger is wrong.
Over current protection was
triggered.
Short circuit protection was
triggered.
The battery capacity is 0 %.
The battery does not give out
current until it is charged up
to 10 % (SOC) or activated by
user.
The display is overheated.
The display is defective.
Troubleshooting
Remedy
Turn the charger off. Connect
a charger with the standard
charge voltage (chapter
"Technical data" on
page 17).
Turn the charger off. Connect
a charger with the standard
charge voltage (chapter
"Technical data" on
page 17).
Turn the device off. Release
some of the load before
switching the device on
again.
Turn the device off. Clear the
short circuit before switching
the device on again.
Charge the device.
Charge the device.
Place the battery pack in a
cool environment.
Contact a service center.
15

Publicité

Table des Matières
loading

Table des Matières