5.5.3 Exemplary settings
Example 1 is the factory setting (since factory settings are entered by computer, all DIP
switches of a new product are set to 'off', except for DS-2).
DS-1 Panel option
DS-2 Panel option
DS-3 Ch. voltage
DS-4 Ch. voltage
DS-5 Frequency
DS-6 Search mode
DS-7 AC-in Limit
DS-8 Store setting
Example 1: (factory setting)
1
No panel or remote
switch connected
2
No panel or remote
switch connected
3, 4
GEL 14.4 V
5
Frequency: 50Hz
6
Search mode off
7
AC-in Limit 12 Amp
8 Store setting: off→ on→ off
Store the settings (DS3-DS7) by changing switch ds-8 from off to on, and then back to off.
The LED's 'charger' and 'alarm' will flash to indicate acceptance of the settings.
6. MAINTENANCE
The Compact does not require specific maintenance. It will suffice to check all connections
once a year. Avoid moisture and oil/soot/vapours, and keep the device clean.
22
off
DS-1
on
DS-2
off
DS-3
off
DS-4
off
DS-5
off
DS-6
off
DS-7
→ ←
DS-8
Example 2
1
2
3,4
5
6
7
8 Store setting: off→ on→ off
off
on
off
on
off
off
on
→ ←
No panel or remote
switch connected
No panel or remote
switch connected
AGM 14,7V
Frequency: 50Hz
Search mode off
AC-in Limit
4 Amp
DS-1
on
DS-2
off
DS-3
on
DS-4
on
DS-5
on
DS-6
on
DS-7
off
→ ←
DS-8
Example 3
1
Panel or remote
switch connected
2
Panel or remote
switch connected
3, 4
Tubular plate 15V
5
Frequency: 60Hz
6
Search mode on
7
AC-in Limit
8 Store setting: off→ on→ off
12 Amp