Figure 7 - De-ashing
Figure 8 - Ash dumping
3.3. Running the stove
Rate of burning is obtained by setting the thermostat
control.
Experience will show you which settings are best for
your situation. In general, the higher position is only
required for lighting and restoring the fire.
Overnight burning :
Riddle and de-ash ; run on high setting the stove for
about 15 - 20 minutes : once the embers are glowing
well, stoke up the fire ; half close the thermostat control
for about 15 - 20 minutes before finally setting the
thermostat control for the night at low position.
De-ashing
Figure 7
Riddle and de-ash before refuelling and every time
grates become congested. Keep fire bed and air inlet
free from ash.
Riddle with vigorous forward and backwards movement
of the riddling tool.
Ash dumping
Figure 8
With the casting handle, pull out control, then insert the
wired handle in riddling control and turn downwards.
Notice de référence
Poêle mixte
1
2
3
4
5
6
7
1 - Eventual smoke exit
on the top
2 - Combustion air
control - Sensing
thermostat.
3 - Flue outlet at rear
4 - Flue baffle
5 - Firebricks
6 - Thermostat shutter
Document n° 729-4EN ~ 03/02/1999
Figure 9 - Description
7 - Air inlet
8 - Main door with
"vitroceramic" glass
9 - Loading door on the
right side
10 - Fuel retainers (2)
11 - Oscillating grates (3)
12 - Ash-pan
Burgundy
8
9
1 0
1 1
1 2
21