4.HOW TO OPERATE THE UNIT
CONTROL PANEL
TEMPERATURE CONTROL PANEL
A) Alarm control and ON/OFF button
B) Temperature control for the refrigerator
C) Temperature control of the freezer
DISPLAY
During the initial start-up, the display screen (including the main light) lights up completely during 3 seconds.
Then you can operate the unit and press the buttons.
Then press the middle button to start the unit Note: The refrigerator and freezer will display average
temperatures at the time of the initial start-up. In the event of a failure, the control will display an error
code. For more details, refer to the error codes section below.
Error codes
LED1\LED2 Flashing at the same time
LED1\LED3 Flashing at the same time
LED1\LED5 Flashing at the same time
LED2\LED4 Flashing at the same time
LED1\ LED4 Flashing at the same time
LED2\ LED5 Flashing at the same time
Description of the Problem
Temperature sensor failure in refrigerating section
Sensor failure in freezing section
Defrost sensor failure in freezing section
Communication failure
Ambient temperature sensor failure
Humidity sensor error