Notes:
-
To ensure accuracy, operating temperature should be within 18ºC~28ºC.
-
Temperature Coefficient= 0.1*(specified accuracy)/ºC (<18ºC or >28ºC).
Range
200mV
2000mV
20.00V
200.0V
600V
-
Input impedance: about 10MΩ,
-
Results might be unstable at mV range when no load is connected. The value becomes
stable once the load is connected. Least significant digit ≤±3.
-
Max input voltage: ±600V, when the voltage ≥610V, "OL" symbol appears.
-
Overload protection: 600Vrms(AC/DC).
Range
200.0mV
2.000V
20.00V
200.0V
600V
-
Input impedance: about 10M
-
Frequency response: 40Hz - 400Hz, sine wave RMS (average response).
-
Max input voltage: ±600V, when the voltage ≥610V, "OL" symbol appears.
-
Overload protection: 600Vrms (AC/DC).
Range
200.0Ω
2.000Ω
20.00kΩ
200.0kΩ
20.00MΩ
200.0MΩ
-
Measurement result = reading of resistor - reading of shorted test leads.
-
Overload protection: 600Vrms (AC/DC).
DC VOLTAGE
Resolution
0.1mV
1mV
0.01V
0.1V
1V
AC VOLTAGE
Resolution
0.1mV
0.001V
0.01V
0.1V
1V
,
RESISTANCE
Resolution
0.1Ω
1Ω
0.01kΩ
0.1kΩ
0.01MΩ
0.1MΩ
Accuracy
±(0.7%+3)
±(0.5%+2)
±(0.7%+3)
±(0.7%+3)
±(0.7%+3)
Accuracy
±(1.0 % + 2)
±(0.7 % + 3)
±(1.0 % + 2)
±(1.2 % + 3)
±(1.2 % + 3)
Accuracy
±(1.0% + 2)
±(0.8% + 2)
±(0.8% + 2)
±(0.8 % + 2)
±(1.2%+3)
±(5.0%+10 )