Notes:
-
Before measuring, switch off the power supply of the circuit and carefully check the
input terminal and range position.
-
lf the range of the measured current is unknown, select the maximum range and then
reduce accordingly.
-
Please replace the fuse with the same type
-
When measuring, please do not connect the test leads with any circuit in parallel.
Otherwise there is a risk of damage to the device and human body.
-
lf the tested curren! is over 10A, each measurement time should be less than 10
seconds and the next test should be after 15 minutes.
Similar to DC Measurement.
Please refer to Section "DC MEASUREMENT (see Figure 3)".
-
The device enters measurement status in 2 seconds after startup.
-
The device automatically shuts down if there is no operation far 15 minutes. You can
wake up the device by pressing any key.
To disable auto shutdown, switch the dial to OFF position, long press HOLD key and
turn on the device.
-
When pressing any key or switching the dial, the buzzer will beep once.
-
Buzzer Notification
1. Input voltage ≥600V (AC/DC), buzzer will continuously beep indicating measure range
is at limit.
2. Input current >10A (AC/DC), buzzer will continuously beep indicating measure range is
al limit.
-
1 min before auto shutdown, 5 continuous beeps. Before shutdown, 1 long beep.
-
Low power warnings:
Vottage ofthe battery <2.5V,
second period. During low power status, the device can still work. Voltage of the battery
<2.2V, a solid
Accuracy: ±(% of reading + numerical value in least significant digit slot), 1 Year Warranty
Ambient temperature: 23ºC ± 5ºC (73,4ºF±9ºF)
Ambient humidity: ≤75% RH
20
10A jack: Fuse 10A/250V
VΩmA jack: Fuse 0.2A/250V
AC MEASUREMENT (see Figure 3)
ADDITIONAL FEATURES
symbol appears and flashes for 3 seconds every 6
symbol appears, the device cannot work.
TECHNICAL SPECIFICATION
Φ
5x20mm
Φ
5x20mm