AQUEENAPRO PERFORMANCE DATA SHEET
AqueenaPro has been tested by an authorised Drinking Water Laboratory for the substances and
conditions shown in the following table.
Substance
Chemical composition
Field parameters
Pressure
Water Temp
Feed Water - Sample Volume
Physiochemical parameters
Turbidity
1)
pH
Hardness and cations
Total hardness ppm
Calcium (dissolved)
Magnesium (dissolved)
Anions
Chloride
Nitrate
N- and P- compounds
Nitrite
Ammonium
Elements and heavy metals
Arsenic (V) (dissolved)
Lead (dissolved)
Cadmium (dissolved)
Iron (dissolved)
Manganese (dissolved)
Mercury (dissolved)
Microbiological
Total Germs (72h@22°C)
Total Germs (24h@37°C)
E.Coli
Enterococcus
1)
Final pH value depends on concentrate of dissolved gaseous fraction of carbon dioxide. High concentrations have tendency to
lower pH.
*Tested under laboratory conditions, actual performance may vary
26
All manuals and user guides at all-guides.com
Unit
bar
°C
L
Unit
NTU
pH
Unit
mgCaCO
/L
3
mgCa/L
mgMg/L
Unit
mgCI/L
mgNO
/L
3
Unit
mgNO
/L
2
mgNH
/L
4
Unit
mgAs/L
mgPb/L
mgCd/L
mgFe/L
mgMn/L
mgHg/L
Unit
[CFU/ml]
[CFU/ml]
[CFU/100ml]
[CFU/100ml]
Reduction Rate [%]
Feed Water
(effl uent drinking water)
3.5
25
100
Feed Water
Reduction Rate [%]
>1
7+10%
Feed Water
Reduction Rate [%]
270±20%
90±20%
20±20%
Feed Water
Reduction Rate [%]
40±20%
120±20%
Feed Water
Reduction Rate [%]
0.50±10%
0.1±20%
Feed Water
Reduction Rate [%]
0.5±20%
0.5±20%
0.5±20%
0.5±20%
0.5±20%
0.5±20%
Feed Water
Reduction Rate [%]
6000-8000
>99.999%
4000-6000
>99.999%
600±20%
Not detectable
600±20%
Not detectable
>85%
neutral
>96%
>98%
>86%
>97%
>91%
>93%
>80%
>99%
>95%
>98%
>96%
>99%
>98%