Note!
Aqueena Pro water purifi er has been designed to be installed under the sink. The initial installation
requires carpentry and plumbing works.
Installation, servicing, maintenance and repairs should only be performed by
Zepter authorised staff .
Recommended side preparation
• Mains connection no more than 1.5 m from the point of installation of AqueenaPro
• Water supply no more than 3 m away
• Drain for rejected water no more than 3 m away
• Space as per the size of AqueenaPro
• It is preferable to install AqueenaPro near a sink so that inlet and reject water
lines are easily available.
Important notes!
1. If you are not using your AqueenaPro for more than two days (48 hrs),
switch off the device and drain the storage tank.
2. To keep the storage tank clean, it should be drained once every 2 days.
3. The buzzer will sound to indicate a fault in the purifi er. If you hear an audible alarm, take action as
reported in the "Display function" section and/or the "Troubleshooting guideline" or call a
service technician for support.
4. Do not try to service the AqueenaPro on your own. Call a service technician/Zepter Service centre
for help.
OPERATING INSTRUCTIONS
Before fi rst use
1.
Install the RO membrane according to the section RO Membrane Installation
2.
Make sure that all connections are secure.
3.
Connect the water purifi er to the mains. Make sure the power connector plug
can plug into the local power socket.
4.
Bypass the water tank, close the water tank valve.
5.
Open water inlet valve and water faucet
6.
Switch on your AqueenaPro. As a start up audio signal will be activated 1 buzz.
7.
Let water run through the system for approx. 5-10 min (system stabilisation)
and check all connections.
Caution!
If you fi nd any leaks, do not proceed further until the leaks are fi xed.
8.
Turn off the water faucet and check if the fl ow of waste water stops
(approx. after 30 s).
9.
If no deviation or leak is found, open the water tank valve and let the system fi ll with water.
10. Drain the fi rst two water tanks before use.