Troubleshooting Procedures (cont.)
Symptoms
10. Pump operates but variable
speed feature does not work.
11. Bath water cools while pump
is operating.
12. Noisy operation.
13. Remote control (if equipped)
does not work.
1019436-2-E
All manuals and user guides at all-guides.com
Probable Causes
B. Control does not work.
A. Motor/pump does not work.
B. Control does not work.
A. Water temperature above 104°
F (40° C).
B. Heater is turned off on user
keypad.
C. Wiring from heater to control is
loose, disconnected or
damaged.
D. Heater does not work.
E. Control does not work.
A. Pump banding straps have not
been cut.
B. Dry or dislodged jet O-ring
(squeal).
A. Batteries improperly installed
or dead.
B. Antenna on wiring harness is
damaged.
C. Remote control not
programmed correctly.
D. Remote control does not work.
E. Control does not work.
16
Recommended Action
B. Replace control.
A. Replace motor/pump.
B. Replace control.
A. Allow bath water to cool.
B. Turn heater on.
C. Check wiring for proper
connections.
D. Replace heater.
E. Replace control.
A. Cut pump banding straps with
tin snips.
B. Remove jet, replace and
lubricate O-ring, and reinstall
jet.
A. Replace batteries.
B. Replace wiring harness.
C. See homeowners guide or
service manual.
D. Replace remote control.
E. Replace control.