Télécharger Imprimer la page

Endress+Hauser FOUNDATION Fieldbus Proline Prowirl 72 Mise En Service page 16

Publicité

Les langues disponibles

Les langues disponibles

0
<
4
Temperature tables compact version
Measuring system Prowirl 72 FOUNDATION Fieldbus (compact version)
• Sensor standard temperature version:
Prowirl 72***-**0********K
Prowirl F/W
at T
= -40 °C ... +70 °C
a
The minimum medium temperature is –40 °C.
• High/low temperature sensor version, high pressure version and Dualsens version:
Prowirl 72***-**1********K; Prowirl 72***-**2********K; Prowirl 72***-**3********K
Prowirl F/W
at T
= -40 °C ... +70 °C
a
The minimum medium temperature is –200 °C.
Measuring system Prowirl 73 FOUNDATION Fieldbus (compact version)
• Sensor:
Prowirl 73***-**4********K
Prowirl F
at T
= -40 °C ... +70 °C
a
The minimum medium temperature is –200 °C.
Temperature tables remote version
Measuring system Prowirl 72 FOUNDATION Fieldbus (remote version)
• Sensor standard temperature version:
Prowirl 72***-**0********K
Prowirl F/W
at T
= -40 °C ... +85 °C
a
The minimum medium temperature is –40 °C.
• High/low temperature sensor version, high pressure version and Dualsens version:
Prowirl 72***-**1********K; Prowirl 72***-**2********K; Prowirl 72***-**3********K
Prowirl F/W
at T
= -40 °C ... +85 °C
a
The minimum medium temperature is –200 °C.
• Transmitter Prowirl 72 FOUNDATION Fieldbus:
Prowirl 72***-********K
Prowirl 72 FOUNDATION Fieldbus
The minimum ambient temperature is –40 °C.
Proline Prowirl 72/73 FOUNDATION Fieldbus
Max. medium temperature [°C] in
T4
T3
130
195
280
Max. medium temperature [°C] in
T4
T3
130
195
290
Max. medium temperature [°C] in
T4
T3
130
195
290
Max. medium temperature [°C] in
T4
T3
130
195
280
Max. medium temperature [°C] in
T4
T3
130
195
290
Max. ambient temperature [°C] in
T4
T3
80
80
T2
T1
280
T2
T1
440
T2
T1
440
T2
T1
280
T2
T1
440
T2
T1
80
80
Endress+Hauser

Publicité

loading