ELECTRICAL CONNECTIONS
REMEMBER -Turn off the power!
NOTE - Control must be installed
within 30 feet of fan.
CAUTION: To reduce the risk of electric shock, this fan must be
installed with an isolating wall control/switch.
Motor to Receiver Electrical Connections:
1
Connect the black wire from the fan to the black wire
marked "TO MOTOR L" on the receiver. Connect the
white wire from the fan to the white wire marked "TO
MOTOR N" on the receiver. Connect the blue wire from
the fan to the blue wire marked "FOR LIGHT" on the
receiver. Secure all the wire connections with the plastic
wire nuts provided.
Receiver to House Supply Wires Electrical Connections:
2
Connect the black (hot) wire from the ceiling to the black
wire marked "AC in L" from the receiver. Connect the
white(neutral) wire from the ceiling to the white wire
marked "AC in N" from the Receiver. Secure the wire
connections with the plastic wire nuts provided.
WARNINGS: Check to see that all connections are tight,
including ground, and that no bare wire is visible at the wire
nuts, except for the ground wire
Outlet box
Black (hot)
Black ("AC IN L")
Black ("to motor L")
Blue (for light)
Blue (for light)
Black (motor)
Fig. 1
©2021 Hinkley Lighting, Inc.
White (neutral)
Green or bare
copper (ground)
White ("AC IN N")
Receiver
White ("to motor N")
(Connect to
Ground
ground wire on
(green)
hanger bracket
if no house
ground wire
exists.)
White (neutral)
08
| hinkley.com