pH set point
Open with the following steps:
Settings key > select pH Set Point > press OK > select desired pH value using "plus" and
"minus" > press OK.
The optimal pH value set appears on the value overview (chapter 4)
Please ensure you only enter pH set points, which are indicated as "CO correct" in the table
in chapter 6.
To make the process even safer for you the carbonate hardness is calculated when set point
is entered. This means the set point is safe for the sh and still provides enough CO for
the plants. In case the device calculates a KH value with more than 1° under the KH of your
aquarium, make sure that you want this value before con rming it with OK.
Auto pH
Open with the following steps:
Settings key > select auto pH > press OK > enter desired KH value using "plus" and "minus" >
press OK.
Enter the KH measured in your aquarium and the device automatically calculates the
corresponding optimal pH value which guarantees a CO content of approx. 22.5 mg/l. This
pH value is automatically stored as the pH set point when you press OK after entering the KH.
This ensures luxuriant plant growth without any danger to the sh. The values on which the
auto pH function is based can be seen as auto pH curve in the table in chapter 6.
Auto pH is factory-set at KH 8 (German degrees).
Tip: If you are unsure of the correct optimal pH value, always use the auto pH function.