Control
When the solenoid valve is switched to automatic (factory setting, see chapter 7.7), the
device controls the following:
Current actual value in the aquarium: pH 7.80. Auto pH has set pH 7.10 as set point. Symbol
for valve status shows "open" and "A" for automatic. CO is now added until a pH value of 7.00*
is attained. The device then closes the solenoid valve and the symbol for valve status shows
"shut" and "A" for automatic.
Now, due to consumption by plants and the compensation from the atmosphere, the CO
level decreases and the pH level slowly increases. After reaching pH 7.20* the solenoid valve
opens again and CO gets added again, till the pH level is dropped to 7.00*, and so on.
* for pre-selected hysteresis (switching point) of 0.1 (factory setting, see chapter 7.6)
pH value, CO2 and carbonate hardness (KH)
The three parameters, pH value, CO content and carbonate hardness are inseparably linked,
as they are interdependent.
How much CO is needed to maintain a particular pH value depends on the KH in the
aquarium. The higher the KH, the more CO is required. Once the KH and pH values are
known, the CO content can be calculated. The following table saves you making the
calculations and also shows the pH values which you can set as a set point without any risk to
your sh.
Never adjust pH set point values arbitrarily, without having determined the KH in your
aquarium, e.g. with a JBL KH test.
CO2 content depending on pH value and KH
CO
(mg/l)
2
KH
pH
2
7,8
1
7,6
2
7,4
2
7,3
3
7,2
4
7,1
5
7
6
6,9
8
6,8
10
6,7
12
6,6
15
6,4
24
6,2
38
Too little CO
CO correct
Too much CO
28
4
6
8
2
3
4
3
5
6
5
7
10
6
9
12
8
11
15
10
14
19
12
18
24
15
23
30
19
29
38
24
36
48
30
45
60
48
72
96
76
114
151
auto pH curve (see chapter 6.1)
10
12
14
5
6
7
8
9
11
12
14
17
15
18
21
19
23
27
24
29
33
30
36
42
38
45
53
48
57
67
60
72
84
75
90
105
119
143
167
189
227
265
16
18
20
9
9
10
12
14
15
19
21
24
24
27
30
30
34
38
38
43
48
48
54
60
60
68
76
76
86
95
96
108
120
121
136
151
191
215
239
303
341
379

Publicité

loading

Ce manuel est également adapté pour:

Proflora co2 control