Switching Off; Bridge/Half-Wave Rectifier (Optional) - Wittur Servogearless WSG-S2.3 Instructions De Service

Moteur d'ascenseur sans engrenage
Table des Matières

Publicité

Electrical installation
5.1.2
Switching suggestions
Abb. 14
INTORQ BFK464 connection diagram
Switching on
K2/K4 must be switched on before or at the same time as K1/K3!

Switching off

Normal - AC switching
-
K2/K4 remain closed
-
K1/K3 open
Emergency stop - DC switching
-
K1/K3 and K2/K4 are opened at the same time
5.2

Bridge/half-wave rectifier (optional)

BEG-561-
The bridge/half-wave rectifiers are used to supply electromagnetic DC spring-applied brakes which are ap-
proved for the use with such rectifiers. Other use is only permitted with the approval of INTORQ.
Once a set over-excitation time has elapsed, the bridge/half-wave rectifiers switch over from bridge rectifi-
cation to half-wave rectification. Depending on the design of the load, an improvement of the switching be-
haviour or a reduction in performance is possible.
INTORQ | BA 14.0197 | 04/2016
230 V AC or 400 V AC
Brake circuit 1
observe the
polarity
Suppressor
circuit
Brake
-
Brake circuit 2
observe the
polarity
Suppressor
circuit
Brake
32

Publicité

Chapitres

Table des Matières
loading

Table des Matières