2.9
Plumbing connections
The plumbing connections have the following characteristics
and dimensions.
=
65 65 65 65
M
U
G
E
R
L
Description
M - System delivery
R - System return
U - Domestic hot water output
E - Domestic hot water inlet
G - Gas supply
W (mm)
2.9.1
Plumbing accessories (optional)
To facilitate plumbing and gas connections to the systems, the
accessories as shown in the table below are available and are to
be ordered separately from the boiler.
DESCRIPTION
Installation plate
Curve kit
Curve and valve kit with connections from DIN
to SIME
Cocks kit
Valve kit with connections from DIN to SIME
Wall mount replacement kit for other makers
Fitting protection Kit
Polyphosphate dosing kit
Dosing recharge kit
kit instructions are supplied with the accessory itself or
NOTE:
are to be found on the packaging.
=
95
Fig. 12
OF
24
Ø 3/4" G
Ø 3/4" G
Ø 1/2" G
Ø 1/2" G
Ø 3/4" G
450
CODE
8075441
8075418
8075443
8091806
8075442
8093900
8094531
8101700
8101710
2.10
Gas supply
boilers leave the factory specifically prearranged for G20 gas
OF
or G30/G31. The G20 models can be converted to function with
G30/G31 using the "specific nozzle kit" (optional) provided by
Climit
on request separately from the boiler.
If changing the type of gas to be used, carry out the entire "GAS
phase of the appliance.
CONVERSION"
The boiler must be connected to the gas mains in full compliance
with the installation standards in force in the country where the
appliance will be used.
Before connecting the boiler to the gas mains, the user must
ensure that:
– the type of gas is correct for the appliance
– the pipes are clean
– the gas supply pipe is the same dimension as or greater than
that of the boiler fitting (G3/4") and with a load loss less than
or equal to that contemplated between the gas mains and the
boiler.
a
WARNING
Once installation has been completed, check that
the joints are air tight as indicated in the installation
Standards.
m
CAUTION
It is recommended that the gas line has a suitable
filter.
2.11
Smoke outlet and combustion air inlet
boilers take in combustion air from the room where the
OF
boiler is installed through the ventilation openings which must
fully comply with Technical Standards.
Permitted outlets
B11BS
Combustion air inlet into the atmosphere and smoke outlet to
open air.
opening for combustion air (6 cm
NOTE:
m
WARNINGS
– The smoke flue and the connection to the flue pipe
must be in compliance with the national and local
standards and legislation in force in the country
where the appliance will be used.
– The use of rigid ducts which are resistant to
temperature, condensate, mechanical stress and
are air-tight is compulsory.
– Outlet ducts which are not isolated are a risk of
danger.
B11BS
B11BS
Fig. 13
x kW).