Climit 24 OF Manuel Pour L'installation Et L'entretien page 36

Publicité

Les langues disponibles

Les langues disponibles

1.6
Main water circuit
1
2
3
4
5
6
8
13
M
U
KEY:
M System delivery
R System return
U Domestic hot water outlet
E Domesti hot water inlet
S Safety valve outlet
G Gas supply
Smoke thermostat
1
2
Heat exchanger (mono-thermal)
Dual sensor (thermal safety/delivery)
3
Combustion chamber
4
Gas valve
5
Domestic hot water heat exchanger
6
Domestic hot water sensor
7
Diverter valve
8
Automatic bleed valve
9
Pump
10
Domestic hot water flow meter
11
Domestic hot water filter
12
System filling
13
System relief valve
14
Water pressure switch
15
Boiler drain
16
System expansion vessel
17
Water pressure gauge
18
Smoke chamber
19
36
19
17
18
9
15
14 S
7
11
12
G
E
R
1.7
Sensors
The sensors installed have the following characteristics:
– Dual sensor (thermal safety/output) NTC R25°C; 10kΩ β25°-
85°C: 3435
– domestic hot water sensor NTC R25°C; 10kΩ β25°-85°C: 3435
– External temperature sensor NTC R25°C; 10kΩ β25°-85°C:
3435
Correspondence of Temperature Detected/Resistance
Examples of reading:
TR=75°C → R=1925Ω
TR=80°C → R=1669Ω.
TR
0°C
1°C
0°C 27279
26135
10°C
17959
17245
20°C
12090
11634
8313
8016
30°C
40°C
5828
5630
50°C
4161
4026
60°C
3021
2928
70°C
2229
2164
10
1669
1622
80°C
90°C
1266
1232
100°C
973
16
1.8
Expansion vessel
The expansion vessel installed on the boilers has the following
characteristics:
Description
Total capacity
Fig. 3
Prefilling pressure
Useful capacity
Maximum system content (*)
(*) Conditions of:
Average operating temperature 70°C (with high temperature
system 80/60°C)
Start temperature at system filling 10°C.
m
CAUTION
– For systems with water content exceeding the
maximum system content (as indicated in the
table) an additional expansion vessel must be
prearranged.
– The difference in height between the relief valve
and the highest point of the system cannot exceed
6 metres. If the difference is greater than 6 metres,
increase the prefilling pressure of the expansion
vessel and the system when cold by 0.1 bar for each
meter increase.
2°C
3°C
4°C
5°C
6°C
7°C
25044
24004
23014
22069
21168
20309
16563
15912
15289
14694
14126
13582
11199
10781
10382
9999
9633
9281
7731
7458
7196
6944
6702
6470
5440
5258
5082
4913
4751
4595
3897
3773
3653
3538
3426
3319
2839
2753
2669
2589
2512
2437
2101
2040
1982
1925
1870
1817
1577
1534
1491
1451
1411
1373
1199
1168
1137
1108
1079
1051
U/M
l
kPa
bar
l
l
EN
IT
8°C
9°C
19489
18706
13062
12565
8945
8622
6247
6033
4444
4300
3216
3116
2365
2296
1766
1717
1336
1300
1024
998
OF
24
8,0
100
1,0
4,0
109