6 Fonctions du terminal compact et des éjecteurs
Extended Device Status 0x008A, Event Category
Paramètre
138 (0x008A)
Description
Extended Device Status – Event Category
Byte
1+2: Event Category of current device status
Access
read only
Value range
0x10 : Device is operation properly
0x21 : Warning, low
0x22 : Warning, high
0x41 : Critical condition, low
0x42 : Critical condition, high
0x81 : Defect/fault, low
0x82 : Defect/fault, high
Extended Device Status 0x008A, Event code
Paramètre
138 ()
Descrip-
Extended Device Status – Event code
tion
Byte
3+4: Event Category of current device status
Datatyp
uint16
Length
2 Byte
Access
read only
Value
Eventcode
range
0x5100
0x5110
0x5112
0x1812
0x1802
0x1811
0x1000
0x8C01
0x180C
0x180D
0x180E
0x8C20...8C2F
0x8D00...8D0F
0x8D10...8D1F
0x8D20...8D2F
0x8D30...8D3F
0x8D40...8D4F
0x8D50...8D5F
Default
-
value
Unit
-
EEPROM
no
Vous trouverez des descriptions de codes d'erreur plus exactes, ainsi que les causes et les solutions dans le
chapitre 11.2.
40 / 68
Eventname
Primary supply voltage (US) too low
Primary supply voltage (US) too high
Secondary supply voltage (UA) too low
Secondary supply voltage (UA) too high
Input pressure too high (>6,3 bar) or too low
(<1, 9bar)
Internal error, user data corrupted
Internal error, Bus fault
Manual mode is active in at least one ejector
Condition Monitoring: primary supply voltage
US outside of operating range
Condition Monitoring: secondary supply vol-
tage outside of operating range
Condition Monitoring: supply pressure outside
of operating range (3,5 ... 5 bar)
Calibration fail, Ejector #1...#16
Measurement range overrun, Ejector #1...#16
Valve protection active, Ejector #1...#16
Evacuation time t1 is greater than limit, Ejec-
tor #1...#16
Leakage rate is greater than limit, Ejector #1...
#16
H1 was not reached, Ejector #1...#16
Free-flow vacuum level too high, Ejector #1...
#16
Status Category
Critical condition, high
Critical condition, high
Critical condition, high
Critical condition, high
Critical condition, high
Defect/fault, high
Defect/fault, high
Warning, low
Warning, high
Warning, high
Warning, high
Defect/fault, low
Defect/fault, low
Warning, high
Warning, low
Warning, low
Warning, high
Warning, low