5 Interfaces
Errors of Control Unit [ro]
BYTE [1]
Error Control Unit
Bit 7
Bit 6
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Condition Monitoring of Control Unit [ro]
BYTE [2]
res
Bit 7
Bit 6
Bit 0:3
CM Control
Unit:
Bit 4:7
res:
EJECTOR STATUS [ro]
BYTE [3] (Ejector 1 - 4)
PP04
AS04
Bit 7
Bit 6
Bit 0
AS01 :
Bit 1
PP01 :
Bit 2
AS02 :
Bit 3
PP02 :
Bit 4
AS03 :
Bit 5
PP03 :
Bit 6
AS04 :
Bit 7
PP04 :
BYTE [4] (Ejector 5 - 8)
PP08
AS08
Bit 7
Bit 6
24 / 68
Bit 5
Bit 4
Internal error: data corruption
Internal error: bus fault
Primary voltage too low
Primary voltage too high
Secondary voltage too low
Secondary voltage too high
Supply pressure too low (<1,9 bar) or too high (>6,3 bar)
Error in one or more ejectors
Bit 5
Bit 4
Condition Monitoring of Control Unit
Bit 0 = Primary Voltage limit
Bit 1 = Secondary voltage limit
Bit 2 = Input pressure limit (3,5 ... 5bar) (hysteresis = 0,2 bar)
Bit 3 = Warning in one or more ejectors
reserved
PP03
AS03
Bit 5
Bit 4
H1 level reached (air saving function) dans l'éjecteur n°1
H2 level reached (part present) dans l'éjecteur n°1
H1 level reached (air saving function) dans l'éjecteur n°2
H2 level reached (part present) dans l'éjecteur n°2
H1 level reached (air saving function) dans l'éjecteur n°3
H2 level reached (part present) dans l'éjecteur n°3
H1 level reached (air saving function) dans l'éjecteur n°4
H2 level reached (part present) dans l'éjecteur n°4
PP07
AS07
Bit 5
Bit 4
Bit 3
Bit 2
CM Control Unit
Bit 3
Bit 2
PP02
AS02
Bit 3
Bit 2
PP06
AS06
Bit 3
Bit 2
Bit 1
Bit 0
Bit 1
Bit 0
PP01
AS01
Bit 1
Bit 0
PP05
AS05
Bit 1
Bit 0