Brochage du TM-C120x pour IM151-1 COMPACT 16DI/16DO DC24V/0,5A
Borne
Tension d'alimentation
1L+
2L+
1M
2M
Entrées TOR
1, 2
3, 4
5, 6, 9, 10,
13, 14, 17, 18,
25, 26, 29, 30,
33, 34, 37, 38
7, 8, 11, 12,
15, 16, 19, 20,
27, 28, 31, 32,
35, 36, 39, 40
21, 22, 23, 24
Sorties TOR
41, 42
61, 62
43, 44
63, 64
45, 46, 49, 50,
53, 54, 57, 58,
65, 66, 69, 70,
73, 74, 77, 78
47, 48, 51, 52,
55, 56, 59, 60,
67, 68, 71, 72,
75, 76, 79, 80
Module IM151-1 COMPACT
Manuel, 03/2007, A5E01077636-01
IM151-COMPACT 16DI/16DO DC24V/0,5A (6ES7151-1CA00-3BL0)
Affectation
L+
L+
M
M
L+
M
DI
, DI
, DI
, DI
,
0
1
2
3
DI
, DI
, DI
, DI
,
4
5
6
7
DI
, DI
, DI
, DI
,
8
9
10
11
DI
, DI
, DI
, DI
12
13
14
15
L+
n. c.
L+
L+
M
M
DO
, DO
, DO
, DO
,
0
1
2
3
DO
, DO
, DO
, DO
,
4
5
6
7
DO
, DO
, DO
, DO
,
8
9
10
11
DO
, DO
, DO
, DO
12
13
14
15
M
Explication
24 V CC
24 VCC (pour raccordement en chaînage)
masse
Masse (pour raccordement en chaînage)
Tension de charge 24 V CC pour groupe
de potentiel 0
Masse pour groupe de potentiel 0
DI
: Signal d'entrée, voie n
n
Alimentation de capteur 24 V CC
Not connected
(max. 30 V CC raccordable)
Tension de charge 24 V CC pour groupe
de potentiel 2
Tension de charge 24 V CC pour groupe
de potentiel 3
Masse pour groupe de potentiel 2
Masse pour groupe de potentiel 3
DO
: Signal de sortie, voie n
n
masse
21