6.0

Maintenance, Service and Storage

6.1
Maintenance: Ensure the WPFRD is kept free of excess paint, grease, dirt or other contaminants as this may cause the various
mechanisms to malfunction. Clean the exterior of the unit as required with a detergent/water solution. After cleaning, lay out or hang all
components to allow the unit to air dry. Lubricate parts as needed.
DO NOT use heat to dry.
DO NOT attempt to disassemble the WPFRD in manners other than those described in this manual.
6.2
Service: This unit is not serviceable or repairable. Replacement components may be purchased as they are removed from service.
6.3
Storage: Hang the WPFRD in a cool, dry, clean environment out of direct sunlight. Position the WPFRD so excess water can drain out.
Avoid exposure to chemical or caustic vapors. Thoroughly inspect the WPFRD after any period of extended storage.
7.0

Inspection

7.1
Pre-Use User Inspection: Perform an inspection before each use in accordance with the recommendations in Table 1 below.
Inspection Requirement
Inspect all components for excessive wear, loose hardware, damage, cracks, corrosion, or other defects.
Snap Hook and Carabiners: Ensure connector gates operate freely. Ensure gates fully close and lock when released.
Web Strap Adjuster: Ensure the Adjuster articulates freely. Operate the Thumb Release Lever and make sure that the cam contacts
the Web Strap.
Web Strap: Inspect the Strap for cuts and excessive wear. Note: This webbing has an internal wear indicator. If you can see the red
inner core, remove from service and replace the Web Strap.
Rope Adjuster: Ensure the adjuster mechanism operates and locks onto the rope. Make sure the adjusters slides freely along the
rope when unlocked.
Rope: Inspect the full length of rope for excessive wear, broken stitching, or broken strands on the outer jacket. If the white inner
core fibers are exposed, remove from service and replace the Rope.
Fixed D-ring: Verify that the D-ring is still fixed in place and inspect for cracks and other wear.
Cleats: Verify that the cleats are securely mounted with no cracks, chips, or dull edges
All labels must be intact and totally legible (see Section 8).
7.2
Inspection Frequency: Inspection is required before each use. Inspection by a Competent Person other than the user is required annually.
7.3
Inspection Checklist: Use Table 1: Guidelines for WPFRD Inspection to inspect the WPFRD.
7.4
Inspection Results: If an inspection reveals defects in or damage to the equipment, inadequate maintenance or activated fall indicators,
remove the equipment from service. If any component fails inspection, remove from service immediately. WPFRD's involved in a fall may
be returned to service after passed inspection by a Competent Person other than the user.
MFRD01 Rev A
Table 1 - Guidelines for WPFRD Inspection
113022
Pass
Fail