After automatic level setting procedure, the general level of the UHF signals can be adjusted from
+10 dB to -9 dB in steps of 1 dB.
General UHF level setting
- Select all the clusters and VHF-UHF.
- Turn the button to choose the Select Filter mode.
- Push the rotary button to enter the selected mode.
- Turn the button to select all UHF.
- Push the button to confirm.
- Turn the button to select the Manual Level mode.
- Push the rotary button to enter the selected mode.
- Turn the button to set the general level, variable from +10 dB to -9 dB.
- Push the button to confirm.
Select Filter
The LED is green.
Select Filter
The LED is now RED colored.
I-II
III
Select Filter
The LED is green.
Manual Level
The LED is green.
Manual Level
The LED is now RED colored.
Manual Level
The LED is green.