Troubleshooting (cont.)
Faucet Troubleshooting Table
Symptoms
4.
Power LED is not
lit.
5. Water drips or
trickles when
faucet is not in
use.
Solenoid Troubleshooting Table
Symptoms
Water leaks from
1.
the solenoid valve.
No audible "click"
2.
when solenoid is
activated.
Handle Switch Troubleshooting Table
Symptoms
1.
Handle LED is lit
when the handle
is closed.
1276182-2-C
Probable Causes
Recommended Action
A. No power to
A. Check the power
the circuit
supply connections to
board.
the circuit board.
B. Power cord is
B. Plug the power cord
plugged into
into an unswitched 120
a switched
VAC outlet (test the
outlet.
outlet with a radio or
other device). Confirm
that the power LED
illuminates.
A. Manual
A. Turn the manual
override is
override clockwise until
partially
it stops; then turn it
engaged.
counterclockwise until
the water drip stops.
Probable Causes
Recommended Action
A. Hose
A. CAUTION: Risk of
connections
personal injury or
are not
product damage. Turn
secure.
off the main power and
water supply. Check all
connections. Make
adjustments as needed.
B. Internal leak.
B. Replace the solenoid
valve assembly.
A. Loose
A. Check solenoid wire
solenoid wire
connection to the circuit
connection.
board.
B. Solenoid
B. Replace the solenoid
valve is not
valve assembly.
functioning.
Probable Causes
Recommended Action
A. Refer to the "Handle
A. Valve
setscrew
LED Adjustment"
needs
section.
adjustment.
18