Specifications
Coverage
Operating voltage
Current consumption
RFI immunity
Alarm contacts
Tamper contacts
Alarm contact hold time
Operating temperature
Storage temperature
Ingress protection (IP) rating
Impact Rating
RFI immunity
Dimensions (L x H x W)
Weight
Supervision Time
In order to continue improving the product, RISCO Group reserves the right to
change specifications and/or designs without prior notice.
Certifications:
Ordering Information
Model
RK66S
14
Up to 5 meters (16 feet) radius
9 to 16 VDC
Typically 20mA @ 12VDC
According to EN50130-4
24VDC, 0.1A, N/C and N/O
24VDC, 0.1A
2.5 seconds
-40°C to +70°C (-40°F to 158°F)
-50°C to +70°C (-58°F to 158°F)
IP43
IK08
According to EN50130-4
102 X 27.5 X 80.2 mm
(4.0" X 1.1" X 3.2")
220 g ( 7.7 oz)
15 min. for 868.65 MHz /
65 min. for 433.92 MHz
Description
Seismic Detector
Seismic Detector